CHANGE FACTORY SETTINGS

Each meter is calibrated at the factory for use with motor oil (see the 

Change Scale Factor

 

section of this manual). The Unit of Measure is also selected prior to shipment.

Programming Version 17 & below

To change the factory settings:

Use a 5/32” Allen

wrench or similar

blunt tool.

1. Press the         button to wake up the 

    meter if the display is blank.

2. To enter the Programming mode turn 

    the unit over. Press and hold down the

    

“PROGRAMMING”

 key located in the 

    access hole for 2 seconds (see picture 

    on left).

3. After the display flashes, the Unit of

    Measurement and Scale Factor are 

    displayed.

4. The current Unit of Measurement will 

    be flashing when the programming 

    mode has been entered.

Location of access hole for 

PROGRAMMING

 Key

Change Unit of Measure

The meter comes with an option to choose 4 different Units of Measure.

Scale Factor Digits

Unit of

Measurement

Programming

Display

1. The actual Unit of Measure is flashing 

    when the Programming Mode is entered.
2. Press the          button to toggle between 

    the four options; PT, QT, GAL, L.
3. When the desired unit of measure is

 

    displayed, press the          button. The 

    Unit of Measure icon stops flashing.

11

Verify Firmware Version

1. The firmware version and code checksum can be displayed by

     holding the            and            button at the same time.

2. The last two digits on the lower right are the firmware version.

3. Meters with version 17 and below use the procedure outlined in

    

Programming Version 17 & below

 in this manual for changing 

    of unit of measure, scale factor and enabling or disabling the EPM functionality.
4.  Meters with version 18 or higher use the procedure outlined in 

Programming Version 

    18 or higher 

in this manual for changing of unit of measure, scale factor and enabling or 

    disabling the EPM functionality.

Содержание 3331-018

Страница 1: ...IN SB3056 Rev C 04 12 Thoroughly read and understand this manual before installing operating or servicing this equipment OPERATION INSTALLATION MAINTENANCE AND REPAIR GUIDE RF ELECTRONIC PRESET METER...

Страница 2: ...pplication and use of the equipment described Should the equipment be used in a manner not specified by Balcrank Products Inc the protection provided by the equipment may be impaired Questions or Serv...

Страница 3: ...Hose 3 Apply Nozzle to Meter 4 METER OPERATION RF MODE 4 History Icon 5 Error Codes 6 METER OPERATION EPM MODE 7 Manual Mode 7 Batch Mode 7 Return to RF Mode 8 OPERATING MODE FUNCTIONS 9 Re settable A...

Страница 4: ...replace worn or damaged parts immediately Do NOT exceed the maximum working pressure level of the lowest rated system comp nent Use only extensions and nozzles that are designed for use with this equi...

Страница 5: ...er automatically shuts off when the dispense batch quantity has been reached A Top Off feature allows additional fluid to be dispensed and tracked after the batch quan tity has been dispensed Upon com...

Страница 6: ...ound all system components according to local state and federal codes Consult the pump user s manual and other system components to ground the following 2 Pump follow manufacturer s recommendations 3...

Страница 7: ...m is clean 6 Close the valve and repeat for all dispense positions Apply Meter to Hose Close the drain valve before starting this procedure If this installation is new or if the fluid in the lines is...

Страница 8: ...battery pack is attached to the meter it automatically enters the RF Mode The trigger is in the locked out position No fluid can be dispensed by the meter until a dis pense order is received from the...

Страница 9: ...itted to the RF system The meter returns to the locked position The meter is now ready to receive another dispense order from the RF system NOTE If the original communication fails the meter automatic...

Страница 10: ...button on the meter To retry communications with the keypad press the Reset button a second time There may be an obstruction blocking the RF signal between the meter and keypad It may be necessary to...

Страница 11: ...shows the amount dispensed 3 When the desired amount has been dispensed release the trigger to stop the flow 4 Press button once to reset the counter display to zero To enter the Batch Mode from the...

Страница 12: ...atch the meter is equipped with an Emergency Override See the Emergency Override section of this manual 3 The user has the option to top off the fluid at the end of a batch To top off the fluid pull t...

Страница 13: ...set back to zero 3 Press the button while viewing Resettotal to set it back to zero 4 Release the button to return to the operating display Re settable Total NOTE The Accumulated Total cannot be rese...

Страница 14: ...r is too low and meter functions are disabled Changing the Batteries The battery compartment is located in the lower case on the underside of the trigger guard 1 Turn the unit over 2 Unscrew the two s...

Страница 15: ...omes with an option to choose 4 different Units of Measure Scale Factor Digits Unit of Measurement Programming Display 1 The actual Unit of Measure is flashing when the Programming Mode is entered 2 P...

Страница 16: ...Save Changes When you are finished programming these options turn the unit over and press the PROGRAMMING key 1 Hold the PROGRAMMING key until the display flashes three times and goes blank 2 Press th...

Страница 17: ...e buttons 5 The current unit of measure will now be flashing indicating that you have entered the programming mode Change Unit of Measure The meter comes with an option to choose 4 different Units of...

Страница 18: ...ection in the manual EPM MANUAL Mode enable disable To disable or enable the EPM mode of the meter 1 Press the button to advance to the AUTO icon on the display there will be no other icons flashing o...

Страница 19: ...tallation Use the Scale Factor show ing on the display not on the trigger Changing the Scale Factor changes the accuracy of the meter potentially causing it to overfill or under fill This has the pote...

Страница 20: ...le Factor Scale Factor Viscosity in Centistokes 65o Samples of Fluids Viscosities and Scale Factors Fluid Viscosity Scale Factor 1 Water Anti Freeze 5 1 044 2 Anti Freeze 18 1 007 3 Brake Fluid 42 1 0...

Страница 21: ...5 bar Operating Temperature Maximum 120o F 50o C Operating Temperature Minimum 20o F 5o C Accuracy Oils 0 5 0 5 Accuracy Anti Freeze 1 5 1 5 5 Digit LCD Display 10 mm High x 5 mm wide Quarts Pints Gal...

Страница 22: ...ITEM PART DESCRIPTION 1 Battery Holder Assembly 2 Bottom Case with Screws 18...

Страница 23: ...1 2 3 ITEM PART DESCRIPTION 1 Rubber Boot 2 Display Assembly 3 RF Register Assembly Not Shown Swivel NPT 19...

Страница 24: ...1 2 3 ITEM PART DESCRIPTION 1 Valve Assembly 2 Gear Service Kit with O ring 3 Trigger Assembly 20...

Страница 25: ...latch for batching Meter not in AUTO mode Meter not reset after prior batch Low batteries Press AUTO button and pro gram batch size Press RESET button Check for battery icon replace batteries push RE...

Страница 26: ...SERVICE BULLETIN SB3056 Rev C 04 12 Revision Log New Release 12 07 Rev A 8 08 Added programming instructions for version 18 and Updated Warranty Statement Rev B 12 08 Added caution about tightening n...

Отзывы: