SUCCESSFUL TEST
The spa will power
Off if the GFCI test is
successful. Power On
the spa at the GFCI.
UNSUCCESSFUL TEST
This indicates that the test has failed.
When this message appears, the spa
will be inoperable, and the spa should
be powered Off. A spa technician
needs to fix the electrical problem.
TP200
USER GUIDE
42369 Rev A2
52
51
Balboa Water Group | Your Single Source Solution
A GFCI is an important
safety device and is
required equipment on
a hot tub installation.
Your spa may be equipped with a GFCI
Protection feature. (UL rated systems only.)
If your spa has this feature enabled by the
manufacturer, the GFCI Trip Test must occur
to allow proper spa function.
Within 1 to 7 days after startup, the spa may
trip the GFCI to test it. (The number of days
is factory programmed.) The GFCI must be
reset once it has tripped. After passing the
GFCI Trip Test, any subsequent GFCI trips
will indicate a ground fault or other unsafe
condition and the power to the spa must be
shut off until a service person can correct the
problem.
Not all control systems trip the GFCI
automatically after a certain number of days.
If the control system does not trip the GFCI
automatically, the GFCI must be tripped
manually.
Forcing the GFCI Trip Test
The installer or spa owner can cause the
GFCI Trip Test to occur at any time by
following the sequence on the next page.
The GFCI should trip within a few seconds
and the spa power should shut down. If the
GFCI does not trip (see next page), shut
down the power to the spa.
The installer or service technician should:
• Manually verify that a GFCI breaker is
installed and that the circuit and spa are
wired correctly.
• Verify the function of the GFCI with its own
test button.
• Restore power to the spa and repeat the
GFCI Trip Test.
Once the GFCI is tripped by the test, reset
the GFCI and the spa will operate normally
from that point. You can verify a successful
test by following the sequence on page 54.
PASS should appear after a temp button is
pressed from the GFCI screen.
The end user should always be
trained to test and reset the GFCI on
a regular basis.
WARNING:
If freezing conditions exist, a GFCI should be
reset immediately or spa damage could result. If
the GFCI does not reset and freezing conditions
exist, drain the spa of all water until the spa is
functional again.
SEQUENCE - TEST THE GFCI
Press the TEMP button. The Set
Temperature will appear and flash.
While the Set Temperature is flashing,
press LIGHT until UTIL appears.
This indicates that you are entering
GFCI Test Mode. (
This feature is not
available on CE rated systems.
)
This screen will display either
ARMD or PASS.
Press TEMP and TRIP will
begin flashing.
Press TEMP to perform the test.
Main Screen
Follow this sequence to perform a GFCI test.
If the test is successful, the spa will power Off.
If the test is unsuccessful, the spa needs to be
powered Off, and a spa technician needs to
fix the electrical problem.
The GFCI test feature is not available
on CE rated control systems.
Flashing characters
Progressive message
Press TEMP button for “action”
Press LIGHT button to “select”
Pause / back to Main Screen / setting not saved
Pause / back to Main Screen / setting saved
Menu Items may or may not appear
SEQUENCE KEY
( View page 2 for full description )
UTILITIES
GFCI TEST FEATURE