
TP200
USER GUIDE
42369 Rev A2
30
29
Balboa Water Group | Your Single Source Solution
Low water flow through the heater. **
There may not be enough water flow through the heater to carry
the heat away from the heating element. Heater start up will begin
again after about 1 min. See “Water Flow Check List” on page 28.
Message
Code *
Heater
Inadequate water flow through the heater. **
There is not enough water flow through the heater to carry the
heat away from the heating element, so the heater has been
disabled. See “Water Flow Check List” on page 28. After the
problem has been resolved, you must press any button on the
panel to reset the control system and begin heater start up.
Message
Code *
*
* *
Control System
View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code.
This message can be reset from the panel with any button press.
The heater may be dry. **
Possible dry heater, or not enough water in the heater to start it.
The spa is shut down for 15 minutes. Press any button to reset
the heater start-up. See “Water Flow Check List” on page 28.
Message Code *
Heater is dry. **
There is not enough water in the heater to start it. The spa is
shut down. After the problem has been resolved, you must
press any button to reset and restart heater start up. See
“Water Flow Check List” on page 28.
Message
Code *
The heater is too hot. **
One of the water temp sensors has detected 118°F (47.8°C)
in the heater and the spa is shut down. You must press any
button to reset when water is below 108°F (42.2°C). See “Water
Flow Check List” on page 28.
Message
Code *
*
* *
View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code.
This message can be reset from the panel with any button press.
PANEL MESSAGES
HEATER RELATED