TROUBLESHOOTING
|
geysair
tm
addendum to the owner’s manual
www.bainultra.com
Printed in Canada. Copyright © september 2012 Bainultra inc. all rights reserved. 45100169
some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
supersedes page 70 of owner’s Manual
23
situation
solutions
air jets seem cool.
a led has a 100 000-hour lifecycle.
• verify wiring and connections.
• unplug and plug again led module power supply. you should see a
light flash in every led. if not, check your power source. if led flash
but still don’t work, please call Bainultra.
Jets are too hot
• deactivate the geysair option, if applicable.
• if the geysair option is installed on the bath, lower the temperature
of the water heater.
leD does not work.
temperature of air injected into bath is directly proportional to the
speed of the turbine. the higher the speed, the warmer the air is. a
simple way to check if your air-heater or heaters are working properly
is to turn on the system at the highest speed (if your control offers a
range of intensities) with no water in the bath (there is absolutely no
risk to the system). after 3 to 5 minutes, the heated backrest or back-
rests should be warm to the touch and jets should also seem warm
when you bring your hands close to them.
• Check the turbine air intake. it should not be too cold nor too warm.
ideally, the temperature should be between 72°f (20°C) and 86°f
(30°C).
• Check that distance between turbine and bath is not too great.
if possible, insulate air line along its entire length. see
turBine
installation
section of this manual.
BatH witH geysair
• the geysair option is not activated on the control panel.
• the geysair hot water supply hose is not connected.
• the geysair hot water supply hose is connected to a cold water supply.
• the hot water hose is too long or not properly insulated.
• the geysair intensity regulator is obstructed.
• for any remote installation, the turbine and the geysair are not
properly connected.