THERMOMASSEUR
®
|
geysair
tm
addendum to the owner’s manual
www.bainultra.com
Printed in Canada. Copyright © september 2012 Bainultra inc. all rights reserved. 45100169
some products, specifications, and services mentioned in this manual are described
in pending patent applications or are protected by patents.
T
H
E
R
M
O
M
A
S
S
E
U
R
®
supersedes page 20 of owner’s Manual
5
aYoURa
®
fReestandInG
installation
1. Bath site
2. installation
1-1
once floor is prepared and level and
recess is cleared around the drain, place
installation template on floor in the
chosen location.
1-2
align template overflow drain hole with
floor drain and make sure recess around
drain matches required measurements.
1-3
mark anchor screw entry points on the
floor.
1-4
remove template and screw anchors
where specified.
TEMPLATE:
AYOURA
Dimensions:
±
1/4" [
±
6mm]
12"
20"
1-1
1-2
2-3
ayoura
®
freestanding - installation
2-1
unscrew both screws on access panel
under the lip and gently remove panel.
2-2
Complete installation of bath drain. make
sure it is watertight.
2-3
install bath on anchors.
2-4
Connect drain and water supply and
finish wiring.
2-5
for geysair-equipped baths,
the geysair
unit must be connected to the hot water
supply with a 3/8 male compression or
1/2” male nPt hose bibb.
a t and a valve
(not supplied)
must be installed at the
hot water intake.
2-6
reinstall access panel.