supersedes page 25 of owner’s Manual
11
origami freestanding design series - installation
2. installation (cont’d)
notes
• to install the origami freestanding design series
on a concrete slab with no place for the passage
of the air inlet pipe to the bathtub: drill a hole
1 5/8 inches in diameter in the skirt. imPortant:
drill the hole 1 1/2 inches above floor level and
protect the bathtub with a piece of wood placed
behind the location to be drilled.
• if a control or options are installed on the bathtub,
a second pipe may be required through which to
feed the cables.
oRIGamI fReestandInG
desIGn seRIes
installation
3/4
1-1
2-1
2-3
2-6
2-7
2-2
2-5
for geysair-equipped baths,
connect
the geysair electrical wire supplied (orange
label) to the turbine wire (also marked with
an orange label) in the junction box.
test
for grounding continuity between the
bath grounding terminal
and the
bath power supply.
failure to perform the
grounding continuity test could result
in serious personal injury.
2-6
use a level or ruler to draw a line on the floor
between contact points between the access
panel arch and the base of the bathtub.
2-7
Position the metal access panel hinge 3/4 of
an inch behind the line drawn in step 2-6.
2-8
screw the hinge in place on the floor
using the slots prjovided. install panel.