5. Have an electrician route and connect a power cord (customer supplied) from the vacuum
pump to the console electrical cabinet terminal strip.
6. Connect the L1, L2, and L3 wires to the terminal block using the Delta (
Δ) wiring on the
motor as shown.
7. Once power is connected to the entire machine, verify that the
motor is rotating in the direction as indicated by the arrow on the
motor cap to create a vacuum.
8. If not, disconnect power to the machine, and switch the L1 and
L3 wires. DO NOT move the ground wire.
9. Once In operation, clean the filter frequently, daily to weekly
depending upon the usage of the system.