34
7.1 Cleaning the strainer:
1. Shut down pump.
2. Close shutoff valves.
3. Open ring nut (160.2), see par. 6.1, lift transparent lid (160.1). Remove
strainer basket (143), clean and replace it. Put transparent lid (160.1) back in
place and tighten ring nut (160.2), see par. 6.1 and 6.3.
4. Open shutoff valves.
5. Restart pump.
7.2
In case of overload the pump is electronically protected and switched off. The
power has to be cut off and the pump must be checked for easy rotation, to do
so turn the motor shaft at the fan side with a screwdriver or similar tool. If turning
the motor shaft requires considerable force, the pump must be checked by an
expert. If it turns easily, remove screwdriver or similar tool. Let the motor cool
down, and restore power supply. This only may happen one more time. Check
power consumption. If the pump is switched off one more time by the electronic
protection the cause of the malfunction is to be determined by an expert (e.g.
blocking of the pump due to impurities, like sand from sweeping or vacuuming
the bottom of the pool). Check power supply and fuses.
7.3
If the pump seizes, it has to be cleaned. Repeated starting of a blocked pump
may cause damage to the motor. In that case any guarantee is voided.
7.4
The leakage pipe on the underside between pump housing and motor must
never be clogged or sealed; otherwise the water in it will rise and the motor will
be damaged! Please make sure that leakage cannot cause consequential
damages! If necessary provide a suitable drip pan.
7.5
Important hints for repair work
Replacement of spare parts is to be carried out by a specialist.
Please send your spare part orders to the swimming pool dealer or pump
service and advise the pump type, the serial number and the number or name
of the required parts. The spare part drawings and spare parts lists can be
downloaded from our website: www.speck-pumps.com
CAUTION
CAUTION
CAUTION
CAUTION