Azbil Infilex AC WY5117C1 Series Скачать руководство пользователя страница 6

AB-6438 

Specifications 

(1/2)

 

Item Specification 

Power supply 

Rated voltage 

24 V AC ± 15 %, 50 Hz/60 Hz 

Power shutdown 
detection 

Max. 19.2 V AC 

Power consumption 

15 VA 

Leakage current 

1 mA or less 

Environmental 
conditions 

Rated operating 
conditions 

Ambient temperature 

C to 50 

Ambient humidity 

10 %RH to 90 %RH (non-condensing) 

Altitude 

Max. 2,000 m 

Vibration 

Max. 5.9 m/s

 (10 Hz to 150 Hz) 

Transport/ 
storage 
conditions 

Ambient temperature 

-20 

C to 60 

Ambient humidity 

5 %RH to 95 %RH (non-condensing) 

Vibration for storage 

Max. 5.9 m/s

(10 Hz to 150 Hz) 

Vibration for transport 

Max. 9.8 m/s

(10 Hz to 150 Hz) 

Installation 

Inside of control panel 

LED indication 
(Operating status LED) 

 

After Infilex AC is turned on, the LED operates as follows in response to the 
Infilex AC operating status. 

Power ON 

ON for several tens of seconds 

Power OFF 

OFF 

Major failure or initializing ON 
Minor failure 

Repetition of 1-second ON, 0.25-second OFF,  0.25-seccond ON, and 
0.25-second OFF 

Engineering mode 

Repetition of 0.25-sec ON, 0.25-second OFF, 0.25-second ON, and 
1.25-second OFF 

Data transmitting 

Repetition of 1-second ON and 1-second OFF 

NC-bus error 

Repetition of 0.25-second ON and 0.25-second OFF 

Backup in the event of power failure  RAM*

1

, RTC*

2

 Lithium 

battery 

backup 

Data file 

Non-volatile memory (flash memory) backup 

Input 

Digital input 

Current 

5 mA typ. 

Voltage 

24 V DC typ. 

Connectable output 

Dry contact or open collector 

Allowable contact 
ON-resistance 

Max. 100 

 

Allowable contact 
OFF-resistance 

Min. 100 k

 

Allowable ON residual 
voltage 

Max. 1 V DC 

Temperature 
input 

Input signal 

RTD (Pt100 (100 

/0 

C), Pt1000 (1000 

/0 

C)) 

Measuring range 

-20 

C to 80 

Voltage input 

Input voltage range 

1 V DC to 5 V DC 

Input impedance 

500 k

 

Output Relay 

output 

(N.O. contact) 

Output method 

Relay output N.O. contact (N.O. contacts share the same common line.) 

Contact rating 

Max. 24 V AC, 0.5 A (Inductive load: cosø = 0.4 or more) 
Max. 24 V DC, 0.5 A 

Minimum applicable load 5 V DC, 10 mA DC 

Relay output 
(N.O./N.C. 
contact) 

Output method 

Relay output, N.O./N.C. contact  (N.O./N.C. contact does not share the 
common line with N.O contact.) 

Contact rating 

Max. 24 V AC, 0.5 A (Inductive load: cosø = 0.4 or more) 
Max. 24 V DC, 0.5 A 

Minimum applicable load 5 V DC, 10 mA DC 

Voltage output 

Output voltage range 

2 V DC to 10 V DC / 0 V DC to 10 V DC 

Min. load resistance 

Min. 10 k

 

Communications NC-bus 

Transmission system 

Current transmission 

Transmission speed 

4800 bps 

Transmission distance 

500 m 

Weight 500 

Material (housing), color 

Modified PPE, light gray 

Terminal connection 

Power supply, ground 

M3 screw terminals (7.62 mm pitch between terminals) 

NC-bus communication, I/O 

Screwless push-in terminals 

PPE: Polyphenylene ether 
RAM: Random-access memory 
RTC: Real-time clock 

 
Notes: 
*1  RAM: A form of data storage that can be accessed directly in any random order.  Stored data is erased when the power is turned off. RAM 

of Infilex AC is backed up by a lithium battery. 

*2  RTC: A computer clock that keeps track of the current time.  RTC of Infilex AC is backed up by a lithium battery. 

Содержание Infilex AC WY5117C1 Series

Страница 1: ...compact AHU Wide range of input output I O combinations Model with the I O combination best suitable for the air conditioning controls you desire such as outdoor air cooling control humidification etc...

Страница 2: ...danger The symbol inside graphically indicates the actual action to be carried out For example the sign on the left indicates general instructions WARNING Be sure to ground the product with ground res...

Страница 3: ...minals If it is shorter the stripped part will not contact the connector Do not use unused spare terminals on the product as relay terminals Doing so might cause malfunction Do not block the ventilati...

Страница 4: ...sor Neoplate Model QY7290 Infilex ZM Model WY5122 Temperature sensor Neopanel Model QY7205 Temperature sensor Infilex VC Model WY5206 SC bus Max 50 units and 1000 m Infilex ZM Model WY5122 Infilex VC...

Страница 5: ...ital input 6 pts voltage output 5 pts relay output 5 pts 1 UT module or Operator Panel integral type connectable 1 2 4 Temperature input 2 pts voltage input 2 pts digital input 8 pts voltage output 6...

Страница 6: ...n collector Allowable contact ON resistance Max 100 Allowable contact OFF resistance Min 100 k Allowable ON residual voltage Max 1 V DC Temperature input Input signal RTD Pt100 100 0 C Pt1000 1000 0 C...

Страница 7: ...standard provided by Furukawa Electric Co Ltd Notes 1 Wiring length shown above is the total wiring length from Infilex AC to a device in connection including the wiring to and from an external termin...

Страница 8: ...e that can be added to Model WY5117C1400 refer to AB 6527 Specifications Instructions of Model RY50XX S S Fan ON OFF Fan ON OFF Humidifier Outdoor air damper Return air temperature Supply air temperat...

Страница 9: ...on of 0 25 second ON and 0 25 second OFF Major failure initializing ON Minor failure Repetition of 1 second ON 0 25 second OFF 0 25 second ON and 0 25 second OFF Engineering mode Repetition of 0 25 se...

Страница 10: ...ition Do not mount Infilex AC with the body tilted Always mount it in the positions as shown in the figure below No other mounting positions are allowed Upright Sideway allowed only when I O module UT...

Страница 11: ...e Notes 1 Pitch between upper lower cable duct and the DIN rail 2 Up to two modules I O module and or UT module integral type Operator Panel can be assembled with the basic unit 3 DIN rail position is...

Страница 12: ...th of I O module UT module or integral type Operator Panel Hatched area in the figure below shows the maintenance clearance Note Up to two modules I O module and or UT module integral type Operator Pa...

Страница 13: ...Doing so might cause malfunction Do not block the ventilation holes of this product Be sure to peel off the protective sheet after installation and wiring Doing so might cause device failure Precautio...

Страница 14: ...e fiber being disconnected from the terminal Note If you pull out the wire diagonally it may be disconnected Arrangement of the wires connected to Infilex AC Notes Neatly place the wires using cable t...

Страница 15: ...sion between Infilex AC and each device use wiring Figure 10 Wiring example System common wiring IMPORTANT Use an isolation transformer Do not ground the secondary side of the transformer Provide a te...

Страница 16: ...that the all the wires are correctly connected Remove the protective sheet from the top surface of Infilex AC Note if some foreign objects possibly come inside Infilex AC from the ventilation holes o...

Страница 17: ...Data Setter Model QY7211B Convert the D SUB connector to the mini DIN connector with the conversion cable Part No 83104995 001 At this time hold the male connector with the mark facing left and inser...

Страница 18: ...ce the remaining battery level cannot be checked by measuring the terminal voltage be sure to replace the battery every 5 years Replace the lithium battery with the power ON If the product has never o...

Страница 19: ...AB 6438 19 Blank page added for page editing purpose...

Страница 20: ...SHRAE 20 AB 6438 Rev 9 0 Jul 2017 Install this product in a panel cabinet This product complies with the following harmonised standards of the Electromagnetic Compatibility Directive EMCD and the Rest...

Отзывы: