![Axis T8504-E Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/axis/t8504-e/t8504-e_user-manual_3039855012.webp)
AXIS T8504–E Outdoor PoE Switch
Web interface
Management uplink port
This parameter has no effect on actual VLAN traffic. The management uplink port assists the
unit to evaluate if the new VLAN configuration might block the unit from being managed
over VLAN from this port. If a possible conflict is detected, an error message appears and the
new VLAN configuration is rejected.
Management VLAN ID
Configure which VLAN ID to be used when managing the unit whenever VLAN is enabled.
VLAN ports configuration
Parameter
Description
VLAN mode
Set VLAN mode to Access or Trunk for each of the Ethernet ports.
Access — VLAN is used only inside the unit to split or limit packet access to specific ports
only. Any incoming VLAN tagged packets received by VLAN access port is discarded. VLAN
tagging is added to the unit packet for VLAN Access incoming packets. Unit internal VLAN
tagging is stripped out for VLAN Access outgoing packets.
Trunk — All Ethernet packets are VLAN tagged. Any untagged VLAN packets received by
VLAN trunk port is discarded.
Access mode VLAN ID
Configure the VLAN ID to be used whenever the port is configured as Access. The unit
internal management port acts as access only. It can only be reached from a single
management VLAN ID.
TRUNK – Filter unknown VLAN
Configure the VLAN Trunk port as filtered or unfiltered.
Enabled — Only data flow from some VLAN IDs, specified in the Trunk VLANs list, passes
through VLAN Trunk port. All other VLAN tagged traffic is discarded.
Disabled — Data flow from all VLAN IDs passes through VLAN Trunk port.
TRUNK VLANs
List the VLAN IDs that may pass through VLAN Trunk port whenever
TRUNK – Filter
unknown VLAN
is enabled.
SNMP configuration
Go to
SNMP configuration
to configure parameters applicable to SNMPv2c and SNMPv3.
SNMPv2c
Parameter
Description
Enable SNMPv2c
Enable or disable SNMPv2c support.
Read community
Configure the SNMPv2c GET community string. Example: public.
Write community
Configure the SNMPv2c SET community string. Example: private.
Trap community
Configure the SNMPv2c Trap community string. Example: public.
System information (MIB-II, v2c/v3)
Parameter
Description
System contact
Configure the SNMP MIB-II system contact OiD string. Example: John.
System name
Configure the SNMP MIB-II system name. Example: My Unit.
System location
Configure the SNMP MIB-II system location. Example: University.
PoE MIB (RFC3621, v2c/v3)
12