AXIS P3301-V Fixed Dome Network Camera
Hardware overview
Caution
To protect the product against power surges, a shielded network cable (STP) must be used between the product and the
network switch. Ensure that the network switch is properly grounded.
Audio in (pink) -
3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out (green) -
3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker
with a built-in ampli
fi
er. A stereo connector must be used for the audio out.
Control button -
The control button is used for:
• Connecting to an AXIS Video Hosting System service. See
page 34
. To connect, press and hold the button for about
1 second until the Status LED
fl
ashes green.
• Connecting to AXIS Internet Dynamic DNS Service. See
page 34
. To connect, press and hold the button for
about 3 seconds.
• Resetting the product to factory default settings. See
page 40
.
Power connector -
Mini DC connector
I/O connector
Note
For technical speci
fi
cations, see
page 46
.
I/O terminal connector -
Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm noti
fi
cations.
In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:
•
Digital output
— For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The
output will show as active (shown under
System Options > Ports & Devices
) if the alarm device is activated.
•
Digital input
— An alarm input for connecting devices that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and
the input becomes active (shown under
System Options > Ports & Devices
).
Function
Pin
Notes
Speci
fi
cations
GND
1
Ground
3.3 V DC Power
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave
fl
oating (unconnected)
to deactivate.
0 to +40 V DC
Digital Output
4
Internal connection to ground when activated,
fl
oating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
Max load =100 mA
Max voltage = +40 V DC
5