UMAX090600 Version 1
Preliminary Documentation – May be Subject to Change
31-48
PGN 65280
Proportional Outputs Feedback
Transmission Repetition:
Data Length:
Data Page:
PDU Format:
PDU Specific:
Default Priority:
Parameter Group Number:
1000s (configurable)
8
0
254
GE
6
PGN Supporting Information:
65280 (0xFF00)
3.3.
CAN Transmit Message Defaults
This section outlines the
default
settings of the CAN-BC-LED Controller CAN transmissions. Recall,
however, that this is a fully programmable unit, such that all these SPNs can be sent on different
PGNs if so desired.
In all the messages shown below, not all the transmitted values have an SPN assigned to them, as
this ECU only uses the SPNs for diagnostic trouble codes. If the SPN is shown as N/A, this means
that the associated value cannot be used to generate DTCs.
The “Battery Charging Status Message” has the following default configuration.
Start Position
Length
Parameter Name
SPN
1 1
byte
Active Battery Charging Stage
N/A
2-3
2 byte
Current Feedback Measured
N/A
4-5
2 byte
Power Supply Voltage Measured
N/A
6-7
2 byte
Battery Voltage Measured
N/A