UMAX090600 Version 1
Preliminary Documentation – May be Subject to Change
37-48
4.5.
Lookup Table Setpoints
The Lookup Table function block is defined in Section 1.5. Please refer to that section for detailed
information about how all these setpoints are used. As this function block’s X-Axis defaults are
defined by the
“X-Axis Source”
selected from
Table 7
, there is nothing further to define in terms of
defaults and ranges beyond that which is described in Section 1.5. Recall, the X-Axis values will be
automatically updated if the min/max range of the selected source is changed.
4.6.
CAN Transmit Setpoints
The CAN Transmit function block is defined in Section 1.10, with addition information in Section 3.3.
Please refer there for detailed information about how all these setpoints are used.
Screen Capture of Default CAN Transmit 1 Setpoints
Name Range
Default
Notes
Transmit Data Source
Drop List
Different for each
See Table 7 for defaults
Transmit Data Number
Per Source
Different for each
See Table 7 for defaults
Transmit PGN
0 to 65535
65280 ($FF00)
See Section 3.3 for defaults
Transmit Repetition Rate
0 to 60,000 ms
1000 ms
0ms disables transmit
Transmit Message Priority
0 to 7
6
Proprietary B Priority
Destination Address (for PDU1)
0 to 255
254 (0xFE, Null Address)
Not used by default
Transmit Data Size
Drop List
Different for each
0 = Not Used (disabled)
1 = 1-Bit
2 = 2-Bits
3 = 4-Bits
4 = 1-Byte
5 = 2-Bytes
6 = 4-Bytes
See Section 3.3 for defaults
Transmit Data Index in Array
(LSB)
1 to 9-DataSize
Different for each
See Section 3.3 for defaults
Transmit Bit Index in Byte (LSB)
1 to 9-BitSize
Different for each
Only used with Bit Data
Types
Transmit Data Resolution
-10
6
to 10
6
Different for each
Transmit Data Offset
-10
4
to 10
4
Different for each