UMAX090600 Version 1
Preliminary Documentation – May be Subject to Change
35-48
Stage 2 Output Type
Drop List
3, Red
See Table 1
Stage 2 Response Type
Drop List
0, Normal On/Off
See Table 2
Stage 2 Blink Rate
0 to 60000 ms
Not Used
Stage 3 Control Source
Drop List
10, Float Stage
See Table 8
Stage 3 Control Number
Depends on Source
1
See Table 8
Stage 3 Output Type
Drop List
1, Green
See Table 1
Stage 3 Response Type
Drop List
0, Normal On/Off
See Table 2
Stage 3 Blink Rate
0 to 60000 ms
Not Used
Stage 4 Control Source
Drop List
9, Absorption Stage
See Table 8
Stage 4 Control Number
Depends on Source
1
See Table 8
Stage 4 Output Type
Drop List
1, Green
See Table 1
Stage 4 Response Type
Drop List
2, Dimming Response
See Table 2
Stage 4 Blink Rate
0 to 60000 ms
Not Used
Stage 5 Control Source
Drop List
8, Bulk Charge Stage
See Table 8
Stage 5 Control Number
Depends on Source
1
See Table 8
Stage 5 Output Type
Drop List
2, Yellow
See Table 1
Stage 5 Response Type
Drop List
2, Dimming Response
See Table 2
Stage 5 Blink Rate
0 to 60000 ms
Not Used
Stage 6 Control Source
Drop List
7, Pre-Charge Stage
See Table 8
Stage 6 Control Number
Depends on Source
1
See Table 8
Stage 6 Output Type
Drop List
2, Yellow
See Table 1
Stage 6 Response Type
Drop List
0, Normal On/Off
See Table 2
Stage 6 Blink Rate
0 to 60000 ms
Not Used
Default Stage Output Type
Drop List
1, Green
See Table 1
Default Stage Response Type
Drop List
1, Blinking Logic
See Table 2
Default Stage Blink Rate
0 to 60000 ms
500ms
4.3.
Battery Charge Setpoints
The Battery Charge function block is defined in Section 1.2. Please refer to that section for detailed
information about how all these setpoints are used.
Screen Capture of Default Battery Charge Setpoints