NOTE: IT’S RECOMMENDED THAT A LICENSED ELECTRICIAN WIRE YOUR
SYSTEM IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES
(NEC).
WARNING: TO REDUCE THE RISK OF ELECTRICAL SHOCK, THE
INCOMING POWER SUPPLY MUST INCLUDE A PROTECTIVE EARTH GROUND.
CT-Series systems are typically controlled with a liquid level switch in a storage tank.
The liquid level switch turns the system on when the water level in the tank drops, and
off when the tank is full. Liquid level switches can be obtained by your local dealer or
distributor. If a liquid level switch is to be used, install it at this time.
PRE-FILTRATION
CT-Series systems are supplied with a 5 micron sediment filter, 10 micron carbon block
and a 1 micron sediment filter. Change the cartridge once a month or when a 10-15 psi
differential exists between the two pre-filters. Ask your local dealer or distributor about
Pre-Filtration systems, if required.
NOTE: THE SYSTEM MUST BE OPERATED ON FILTERED WATER ONLY.
PUMP
The pump type used on the CT-Series systems is multi-stage centrifugal carbon steel
pumps. These pumps are also available as an option in stainless steel.
Follow these guidelines to ensure proper operation of the pump:
•
The pump must
NEVER
be run dry. Operating the pump without sufficient feed
water will damage the pump.
•
ALWAYS
feed the pump with filtered water. The pump is susceptible to damage
from sediment and debris.
Содержание CT-4000
Страница 1: ...Reverse Osmosis User s Manual Model CT 4000 CT 5000 CT 7000 CT 7000 Pictured...
Страница 2: ...2 ENGF 107 REV A 01 11 2011 AXEON Water Technologies This Page Left Blank...
Страница 10: ...10 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF1 STANDARD...
Страница 11: ...11 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF4 OPTIONAL...
Страница 12: ...12 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF5 OPTIONAL...
Страница 13: ...13 ENGF 107 REV A 01 11 2011 AXEON Water Technologies NF3 OPTIONAL...
Страница 14: ...14 ENGF 107 REV A 01 11 2011 AXEON Water Technologies NF4 OPTIONAL...
Страница 15: ...15 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 CT 5000 CT 7000 SYSTEM IDENTIFICATION FIGURE 1A...
Страница 17: ...17 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1B FIGURE 1C...
Страница 18: ...18 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1D FIGURE 1E...
Страница 39: ...39 ENGF 107 REV A 01 11 2011 AXEON Water Technologies DRAWINGS FIGURE 5...
Страница 40: ...40 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 6...
Страница 41: ...41 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 7...
Страница 42: ...42 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 8...
Страница 47: ...47 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 FLOW DIAGRAM...
Страница 48: ...48 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 5000 FLOW DIAGRAM...
Страница 49: ...49 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 7000 FLOW DIAGRAM...
Страница 50: ...50 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 110 220V 50 60 Hz 1 PHASE ELECTRICAL SCHEMATIC Minitrol...
Страница 51: ...51 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 208 220V 50 60 Hz 3 PHASE ELECTRICAL SCHEMATIC Minitrol...
Страница 54: ...54 ENGF 107 REV A 01 11 2011 AXEON Water Technologies...