background image

16 

 

ENGF-107 REV. A 01/11 

 

          © 2011 AXEON Water Technologies 

NUMBER IDENTIFICATION 

 
1.  Solenoid Valve – Turns On/Off Feed Water  
2.  5 Micron Sediment – Removes particulates 
3.  10 Micron Carbon Block - Removes Chlorine 
4.  1 Micron Sediment – Removes particulates 
5.  Pressure Gauge - Measures feed pressure 
6.  Pressure Gauge - Measures pressure after filters 
7.  Pressure Gauge - Measures pump pressure 
8.  Pressure Gauge – Measures concentrate pressure 
9.  Computer Control - Controls RO system  
10. Recycle Valve – Recycles concentrate back to feed (If Applicable)  
11. Concentrate Valve – Controls flow of concentrate (waste) water to the drain 
12. RO Pump & Motor - Pressurizes RO System 
13. Throttle Valve – Controls flow of the pump  
14. Flow Meter - Measures flow of permeate water 
15. Flow Meter - Measures flow of concentrate (waste) water 
16. Flow Meter - Measures flow of concentrate recycle water (If Applicable) 
17. Pressure Switch – Turns the Pump off at 15 PSI feed pressure 
18. Permeate check Valve- Protects membranes from back pressure  
19. Pressure Vessels – Houses Membrane Elements  
20. TDS Meter – Reads the quality of the permeate water 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CT-4000

Страница 1: ...Reverse Osmosis User s Manual Model CT 4000 CT 5000 CT 7000 CT 7000 Pictured...

Страница 2: ...2 ENGF 107 REV A 01 11 2011 AXEON Water Technologies This Page Left Blank...

Страница 3: ...EM IDENTIFICATION 15 CT 4000 MEMBRANE FLOW DIAGRAM 20 CT 5000 MEMBRANE FLOW DIAGRAM 21 CT 7000 MEMBRANE FLOW DIAGRAM 22 SYSTEM PURGING 23 INITIAL START UP 24 DESIGN BASIS FOR CT 4000 CT 5000 CT 7000 2...

Страница 4: ...OG MUST BE MAINTAINED AND COPIES WILL NEED TO BE SENT TO YOUR LOCAL DEALER OR DISTRIBUTOR FOR REVIEW NOTE PRIOR TO OPERATING OR SERVICING THE REVERSE OSMOSIS SYSTEM THIS USER S MANUAL MUST BE READ AND...

Страница 5: ...NOTE HIGHER TDS AND OR LOWER TEMPERATURES WILL REDUCE THE SYSTEM S PRODUCTION REJECTION RECOVERY FLOW RATES CT Series reverse osmosis systems are designed to produce permeate water at the capacities...

Страница 6: ...rmula Recovery Product Water Flow Rate Feed Water Flow Rate x 100 Example 40 2 78 7 0 x 100 NOTE ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS TYPICALLY GALLONS PER MINUTE GPM SYSTEM REQUIREMENTS...

Страница 7: ...GGRESSIVE TO SOME PLUMBING MATERIALS SUCH AS COPPER PIPING CONCENTRATE WASTE WATER CONNECTION Locate the 1 connection labeled concentrate and attach to a drain Run the concentrate line to an open drai...

Страница 8: ...all it at this time PRE FILTRATION CT Series systems are supplied with a 5 micron sediment filter 10 micron carbon block and a 1 micron sediment filter Change the cartridge once a month or when a 10 1...

Страница 9: ...system s model and pump size MOUNTING The free standing system should be bolted down in compliance with local regulation standards or securely fastened MEMBRANE ELEMENTS CT Series reverse osmosis sys...

Страница 10: ...10 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF1 STANDARD...

Страница 11: ...11 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF4 OPTIONAL...

Страница 12: ...12 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF5 OPTIONAL...

Страница 13: ...13 ENGF 107 REV A 01 11 2011 AXEON Water Technologies NF3 OPTIONAL...

Страница 14: ...14 ENGF 107 REV A 01 11 2011 AXEON Water Technologies NF4 OPTIONAL...

Страница 15: ...15 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 CT 5000 CT 7000 SYSTEM IDENTIFICATION FIGURE 1A...

Страница 16: ...Controls RO system 10 Recycle Valve Recycles concentrate back to feed If Applicable 11 Concentrate Valve Controls flow of concentrate waste water to the drain 12 RO Pump Motor Pressurizes RO System 13...

Страница 17: ...17 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1B FIGURE 1C...

Страница 18: ...18 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1D FIGURE 1E...

Страница 19: ...19 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1F Note A portion of the frame has been removed to expose components...

Страница 20: ...20 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 MEMBRANE FLOW DIAGRAM FIGURE 1G Note Black arrows represent concentrate water and white arrows represent permeate water...

Страница 21: ...21 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 5000 MEMBRANE FLOW DIAGRAM FIGURE 1H Note Black arrows represent concentrate water and white arrows represent permeate water...

Страница 22: ...22 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 7000 MEMBRANE FLOW DIAGRAM FIGURE 1I Note Black arrows represent concentrate water and white arrows represent permeate water...

Страница 23: ...S PROCEDURE 1 Redirect permeate water to the drain for this procedure 2 Fully open the concentrate valve 11 Counter Clockwise Figure 1B Page 16 3 Fully close the recycle valve 10 Clockwise If Applicab...

Страница 24: ...cle valve 10 If Applicable and the throttle valve to the designed flow and pressure Figure 3 Page 27 7 Inspect the system for leaks 8 Allow the system to run for one hour to flush the preservative sol...

Страница 25: ...25 ENGF 107 REV A 01 11 2011 AXEON Water Technologies DESIGN BASIS FOR CT 4000 CT 5000 CT 7000 WARNING NEVER EXCEED THE MAXIMUM PRESSURE RATING OF YOUR SYSTEM...

Страница 26: ...Shut down the system for extended periods Close the throttle valve completely Operate the system with insufficient feed flow Operate the pump dry OPERATION MAINTENANCE The reverse osmosis process cau...

Страница 27: ...URE SWITCH The low pressure switch shuts off the system when the feed water pressure drops below 15 PSI preventing damage to the pump The system restarts automatically when there is a constant pressur...

Страница 28: ...ogies Example 98 5 550 8 25 550 x 100 Rejection Feed TDS Product TDS Feed TDS x 100 ADJUSTING THE THROTTLE VALVE To decrease the pressure turn the handle clockwise To increase the pressure turn the ha...

Страница 29: ...f necessary 4 Make sure that all parts are clean and free from dirt Examine the brine seal and permeate tube for nicks or cuts Replace the O rings or brine seal if damaged 5 Flow directions should be...

Страница 30: ...f necessary 5 With a smooth and constant motion push the membrane element into the housing so the brine seal enters the housing without coming out of the brine seal groove 6 Re install the end caps by...

Страница 31: ...31 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 4 View from the back of CT 4000 CT 5000 and CT 7000 reverse osmosis system...

Страница 32: ...g lines of the system must be completely drained Any water remaining in the plumbing of a system may freeze causing serious damage Preparing system for storage 1 Totally immerse the elements in the me...

Страница 33: ...e housings removing the pre filter cartridges and drain the water from the housings 7 Disconnect the tubing from the connectors on the permeate and concentrate inlets and outlets 8 Fully open the conc...

Страница 34: ...ane Replace membrane Exceeding maximum feed water temperature See temperature correction sheet Poor permeate quality Low operating pressure See low inlet pressure Damage product tube o rings Inspect a...

Страница 35: ...thin 20 of the rated production after correcting the feed water temperatures above or below 77 F Check your permeate flow meter to determine the permeate flow rate NOTE TO DETERMINE THE TEMPERATURE CO...

Страница 36: ...RE CORRECTION FACTORS FOR MEMBRANE Find the temperature correction factor TCF from the table below Divide the rated permeate flow at 77 F by the temperature correction factor The result is the permeat...

Страница 37: ...to obtain the correct flow Example 5 gpm 59 F 5 1 42 3 52 gpm 5 gpm 77 F 5 1 5 gpm 5 gpm 84 F 5 0 89 5 62 gpm SERVICE ASSISTANCE If service assistance is required please complete the following process...

Страница 38: ...Of ____________________ System Serial ____________________ Date Time Hour of Operation Filter inlet pressure psi Filter outlet Pressure psi Concentrate Pressure psi Pump Discharge Pressure psi Feed F...

Страница 39: ...39 ENGF 107 REV A 01 11 2011 AXEON Water Technologies DRAWINGS FIGURE 5...

Страница 40: ...40 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 6...

Страница 41: ...41 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 7...

Страница 42: ...42 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 8...

Страница 43: ...43 ENGF 107 REV A 01 11 2011 AXEON Water Technologies Note A portion of the frame has been removed to expose components FIGURE 9...

Страница 44: ...E LOW N O 15 30 1 4 FNPT 8 1 200789 PUMP MULTI STAGE 1 5HP 110 220V 1PH 9 1 200994 VALVE GLOBE SS 3 4 FNPT 10 4 200379 MEM HF1 4040 SYSTEMS 11 4 200527 MHS PVC 4040 1 2 x 1 2 SP FNPT SYSTEMS 12 2 2008...

Страница 45: ...E LOW N O 15 30 1 4 FNPT 8 1 200789 PUMP MULTI STAGE 1 5HP 110 220V 1PH 9 1 200994 VALVE GLOBE SS 3 4 FNPT 10 4 200379 MEM HF1 4040 SYSTEMS 11 4 200527 MHS PVC 4040 1 2 x 1 2 SP FNPT SYSTEMS 12 2 2008...

Страница 46: ...E LOW N O 15 30 1 4 FNPT 8 1 200789 PUMP MULTI STAGE 1 5HP 110 220V 1PH 9 1 200994 VALVE GLOBE SS 3 4 FNPT 10 4 200379 MEM HF1 4040 SYSTEMS 11 4 200527 MHS PVC 4040 1 2 x 1 2 SP FNPT SYSTEMS 12 2 2008...

Страница 47: ...47 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 FLOW DIAGRAM...

Страница 48: ...48 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 5000 FLOW DIAGRAM...

Страница 49: ...49 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 7000 FLOW DIAGRAM...

Страница 50: ...50 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 110 220V 50 60 Hz 1 PHASE ELECTRICAL SCHEMATIC Minitrol...

Страница 51: ...51 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 208 220V 50 60 Hz 3 PHASE ELECTRICAL SCHEMATIC Minitrol...

Страница 52: ...52 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 110 220V 50 60 Hz 1 PHASE ELECTRICAL SCHEMATIC Minitrol IF...

Страница 53: ...53 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 208 220V 50 60 Hz 3 PHASE ELECTRICAL SCHEMATIC Minitrol IF...

Страница 54: ...54 ENGF 107 REV A 01 11 2011 AXEON Water Technologies...

Отзывы: