34
ENGF-107 REV. A 01/11
© 2011 AXEON Water Technologies
REVERSE OSMOSIS TROUBLESHOOTING
SYMPTOMS
POSSIBLE CAUSES
CORRECTIVE ACTION
Low Inlet Pressure
Low supply pressure
Increase Inlet Pressure
Cartridge filters plugged
Change Filters
Solenoid valve malfunction
Replace Sol. Valve and/or Coil
Motor may not be drawing correct
current
Use clamp-on amp meter to check
the motor amp draw.
Concentrate valve might be damage
Replace Needle Valve
Leaks
Fix any visible leaks
Low Permeate Flow
Low inlet flow
Adjust concentrate valve
Cold feed water
See temperature correction sheet
Low operating pressure
See low inlet pressure
Defective membrane brine seal
Inspect & or replace brine seal
Fouled or Scaled membrane
Clean membranes
High permeate flow
Damaged product tube o-rings
Inspect and/or replace
Damaged or oxidized membrane
Replace membrane
Exceeding maximum feed water
temperature
See temperature correction sheet
Poor permeate quality
Low operating pressure
See low inlet pressure
Damage product tube o-rings
Inspect and/or replace
Damaged or oxidized membrane
Replace membrane
Membrane fouling
Metal Oxide Fouling
Improve pretreatment to remove
metals. Clean with Acid Cleaners.
Colloidal Fouling
Optimize pretreatment for colloid
removal. Clean with high pH anionic
cleaners.
Scaling (CaSO4, CaSO3, BaSO4,
SiO2)
Increase acid addition and
antiscalant dosage for CaVO3 and
CaCO4. Reduce recovery. Clean
with Acid Cleaners
Biological Fouling
Shock dosage of Sodium Bi-Sulfate.
Continuous feed of Sodium Bi-
Sulfate at reduced pH.
Chlorination and de-chlorination.
Replace cartridge filters.
Organic Fouling
Activated Carbon or other
pretreatment. Clean with high pH
cleaner.
Chlorine Oxidation
Check Chlorine feed equipment and
de-chlorination system.
Abrasion of membrane by Crystalline
Material
Improve pretreatment. Check all
filters for media leakage.
Содержание CT-4000
Страница 1: ...Reverse Osmosis User s Manual Model CT 4000 CT 5000 CT 7000 CT 7000 Pictured...
Страница 2: ...2 ENGF 107 REV A 01 11 2011 AXEON Water Technologies This Page Left Blank...
Страница 10: ...10 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF1 STANDARD...
Страница 11: ...11 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF4 OPTIONAL...
Страница 12: ...12 ENGF 107 REV A 01 11 2011 AXEON Water Technologies HF5 OPTIONAL...
Страница 13: ...13 ENGF 107 REV A 01 11 2011 AXEON Water Technologies NF3 OPTIONAL...
Страница 14: ...14 ENGF 107 REV A 01 11 2011 AXEON Water Technologies NF4 OPTIONAL...
Страница 15: ...15 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 CT 5000 CT 7000 SYSTEM IDENTIFICATION FIGURE 1A...
Страница 17: ...17 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1B FIGURE 1C...
Страница 18: ...18 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 1D FIGURE 1E...
Страница 39: ...39 ENGF 107 REV A 01 11 2011 AXEON Water Technologies DRAWINGS FIGURE 5...
Страница 40: ...40 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 6...
Страница 41: ...41 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 7...
Страница 42: ...42 ENGF 107 REV A 01 11 2011 AXEON Water Technologies FIGURE 8...
Страница 47: ...47 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 4000 FLOW DIAGRAM...
Страница 48: ...48 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 5000 FLOW DIAGRAM...
Страница 49: ...49 ENGF 107 REV A 01 11 2011 AXEON Water Technologies CT 7000 FLOW DIAGRAM...
Страница 50: ...50 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 110 220V 50 60 Hz 1 PHASE ELECTRICAL SCHEMATIC Minitrol...
Страница 51: ...51 ENGF 107 REV A 01 11 2011 AXEON Water Technologies 208 220V 50 60 Hz 3 PHASE ELECTRICAL SCHEMATIC Minitrol...
Страница 54: ...54 ENGF 107 REV A 01 11 2011 AXEON Water Technologies...