5.3 RF Balancing
The BSF-3302 RF Balancing procedure can be performed manually (the automatic option specified
in section 5.3.2 will be available in the future) via the OMU II web interface.
5.3.1 Manual RF Balancing
NOTE: If connected locally, enter the BSF-3302 Home screen and skip to step 2.
The manual balancing procedure consists of the following steps:
●
Verifying the DL RF output level is maximized by setting the required DL attenuation of
the signal.
●
Setting the UL attenuation according to the DL.
●
In case of noise, adjusting the UL attenuation to reduce noise
To balance the BSF-3302 UL and DL outputs
1.
Access the BSF-3302 Configuration window:
●
Click on the
Nodes
button. The below pane appears
●
Click
Control
next to the node to be balanced.
Figure 5-4: OMU II System Nodes window
2.
The resulting pane can be displayed in two views:
●
Basic
– default view (
Basic
button)
●
Advanced
– provides more information
(Advanced
button)
The dialog below shows an example of the Basic (default) view.
NOTE: The various elements monitoring options are described in detail in section 7.