Axell BSF-3302 61-200001 Series Repeater
Product Description and U
ser’s Manual
© Axell Wireless Ltd
Doc. No. PN 3302 61-200001 Series-UM Rev. 1.0
33
4.7.2.1 Backup Battery
●
A rechargeable battery pack is mounted in a small recess on the PSU module. The PSU
module also includes charging and supervision electronics.
●
The backup battery will provide the Control Module and modem with enough capacity to
send an alarm in case of input power failure.
●
The battery can be switched on and off. The switch is placed adjacent to the main power
on/standby switch on the PSU module.
●
At delivery the back-up battery is connected.
●
The battery is replaced by removing the restraining clip and lifting the battery pack out of
the recess and disconnecting the cable.
Figure 4-13: Backup Battery
4.7.2.2 Connecting the Power Source
●
The BSF unit is supplied with an AC Mains cable with a free socket which mates with the
panel plug on the side of the unit.
●
Power Source: 115 VAC 60 Hz
●
The power supply module
has a switch which allows it to be set in “on” position or in
“stand by”.
NOTE: With the PSU module on/standby switch in the standby position the repeater is still
connected to the AC power supply but is not operational.
●
To disconnect the repeater completely from the AC supply the PSU on/standby switch
should be set in the standby position and the mains flying socket removed from the panel
plug on the side of the repeater.
Connector