Axell BSF-3302 61-200001 Series Repeater
Product Description and User’s Manual
© Axell Wireless Ltd
Doc. No. PN 3302 61-200001 Series-UM Rev. 1.0
30
3.
Remove any protective caps from the SC/APC connector and SC/APC receptacle and mate
the free connector to the receptacle.
NOTE: Clean the fiber connector before connecting it to the system. See instruction in
Appendix B - F/O Cleaning Procedure.
4.
To ensure IP65 compliancy and provide a degree of strain relief rubber sealing insert should
be employed. The insert has a slit along one side; on the outside of the repeater, pass the
fiber optic cable through the slit in the insert and then slide the insert along the cable and into
the cable entry gland.
5.
With the rubber sealing insert sitting inside the
cable entry gland, tighten the exterior nut until it
grips the rubber sealing insert - the exterior nut
acts as a collet gripping the rubber sealing insert.
Check again that there is enough cable slack
between the cable gland and the fiber optic
converter module, the cable should not be too
tight.