Jet Cleaner TANKO-JM
82/90
Translation of the original Operating / Installation Instructions 2016/12
8 Faults
8.2
Faults and Remedial Action
Fault
Cause
Remedy
Cleaning head and/or
nozzle carrier not rotating
or rotating unevenly.
–
There is no media pressure on the
device.
–
Open the shut-off valve for the
medium.
–
Pressure of the cleaning agent too
low.
–
Increase the pressure (adhere to
the max. permitted pressure).
–
Pressure of the cleaning agent too
high.
–
Reduce the pressure.
–
Excessive friction due to wear on
the bushings and/or bearings.
–
Check the bushings and/or
bearings for wear, clean or replace
them.
–
Actuator unit in the device
damaged or contaminated with
deposits or foreign objects. The
teeth of the spur gears jam.
–
Clean the inside of the device and
remove any foreign objects.
Replace the spur gears.
–
The cleaning head collides with
installed components.
–
Eliminate the interfering contours.
–
Nozzles are blocked mechanically
by interfering contours.
–
Check the position in the
container.
–
Nozzle jet too close to surrounding
components. Due to high media
pressure (recoil).
–
Increase the distance to
surrounding components.
–
Filter or nozzles blocked.
–
Clean the filter or nozzles.
Effectiveness of cleaning
is inadequate.
–
Nozzles soiled or blocked.
–
Clean or replace the nozzles.
–
Pressure of the cleaning agent too
low.
–
Increase the pressure (adhere to
the max. permitted pressure).
–
Volume flow rate too low.
–
Increase the volume flow rate
–
Filter blocked.
–
Clean or replace the filter.
Jet pattern not ideal.
–
No jet concentrators in the
nozzles.
–
Retrofit jet concentrators.
–
Nozzles soiled.
–
Clean the nozzles.
–
Nozzles damaged.
–
Replace the nozzles
Process or media
connection leaking.
–
Seal defective.
–
Replace the seal.
–
Connections have come loose.
–
Check the tightening torque
values of the screw connections.
Volume flow rate too high.
–
Increased leakage due to heavily
worn bushings or bearings.
–
Replace the bushings or bearings.
Table 8.2-1: Operating faults
–
cause and remedy
If the specified measures are NOT successful, please contact AWH.
In the event of return shipment (e.g. repair / servicing / return), a hazardous substance
declaration must be enclosed with the device in accordance with the Hazardous Substance
Directive (GefStoffV).
Request the form for the hazardous substance declaration from AWH.
Содержание TANKO JM100
Страница 10: ...Jet Cleaner TANKO JM VIII Translation of the original Operating Installation Instructions 2016 12 Contents...
Страница 100: ...Jet Cleaner TANKO JM 90 90 Translation of the original Operating Installation Instructions 2016 12 Appendices...
Страница 101: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group Notizen...
Страница 102: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...
Страница 103: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...