Jet Cleaner TANKO-JM
38/90
Translation of the original Operating / Installation Instructions 2016/12
5 Installation
Interface B
The connection to the container must be designed to that it is compatible with the process connection
[PC] for the downpipe [DP]. The process connection [PC] must be fastened permanently and leak-tight
to the connection on the container (e.g. screwed or clamping) and secured to prevent it from coming
loose.
WARNING
NON-threaded process connections [PC], e.g. detachable connections with a clamp or
catch design, may come loose unintentionally!
There is a risk of fluids getting in or spraying out (carryover of zones).
Process connections [PC] with a clamp or catch design must:
–
be self-locking (e.g. mechanical locking with safety lock) or
–
provided with an additional securing mechanism to prevent them from coming loose accidentally.
The operating company is solely responsible for fastening the device to the container.
Interface C
NOTE
Excessively small installation openings on the container or components (e.g. agitators) in the
container! Nozzles collide during installation!
Damage to the device. The nozzle carrier may come loose.
The nozzles must NOT collide!
1. Check the following before inserting the device into the container:
–
The minimum dimension for the installation opening (see
section 3.3
–
Presence of interfering contours on surrounding components in the container and
–
That the nozzle carrier with nozzles is firmly in place on the cleaning head.
2. Insert the device into the container through the installation opening with the utmost care.
NOTE
“
Installation opening - stationary device
”
Before installation, align the position of the nozzles if necessary by rotating the cleaning
head/nozzles.
Fasten the cleaning head/device inside the container.
–
Provided that proper installation and assembly/removal of the cleaning head/device inside the
container is assured and
–
The diameter of the installation opening on the container is at least 5 mm greater than the outer
diameter of the downpipe [DP].
NOTE
“
Installation opening - mobile device
”
Smaller installation openings on the container
“
for mobile use
”
of the device, as specified in
section 3.3
, are permitted only:
If the cleaning head fits through the installation opening with the nozzles in any position during
installation and removal of the device (e.g. by using shorter nozzles) and
a safety clearance of at least 5 mm all around the device between the device and the installation
opening is ensured.
Содержание TANKO JM100
Страница 10: ...Jet Cleaner TANKO JM VIII Translation of the original Operating Installation Instructions 2016 12 Contents...
Страница 100: ...Jet Cleaner TANKO JM 90 90 Translation of the original Operating Installation Instructions 2016 12 Appendices...
Страница 101: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group Notizen...
Страница 102: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...
Страница 103: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...