
Jet Cleaner TANKO-JM
5 Installation
Translation of the original Operating / Installation Instructions 2016/12
37/90
Only use the wrench flat on the connection cover for screwing on and unscrewing the device on the
pipe for the media supply (see
Figure 5.2-7: Assembly of threaded connection (example JM100)
Figure 5.2-7: Assembly of threaded connection (example JM100)
1. Remove the screw cap/sealing plug from the media connection [MC].
2. Screw the female thread in the connection cover (01) to the male thread on the connection line for
the media supply.
NOTE
There is a risk of damage to the thread if the tightening torque applied for the threaded
connection between the connection cover and the pipe is excessive!
The tightening torque value for the threaded connections between the connection cover and pipe
depends on the material of the pipe for the media supply.
3. Tighten the threaded connection between the connection cover and the pipe using an open-ended
wrench or adjustable pliers wrench, as shown in
Содержание TANKO JM100
Страница 10: ...Jet Cleaner TANKO JM VIII Translation of the original Operating Installation Instructions 2016 12 Contents...
Страница 100: ...Jet Cleaner TANKO JM 90 90 Translation of the original Operating Installation Instructions 2016 12 Appendices...
Страница 101: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group Notizen...
Страница 102: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...
Страница 103: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...