Jet Cleaner TANKO-JM
7 Maintenance
Translation of the original Operating / Installation Instructions 2016/12
67/90
11. To secure the connection against loosening, screw 2x threaded pins (19) into the shaft-axle
connection (15) and tighten them with a hexagon socket wrench.
12. Press jet concentrators (09) in all nozzles (08) and check that they are firmly in place.
13. Screw and tighten nozzles (08) into the nozzle carrier (18).
2) Assembly - Actuator Unit
1. Insert a sliding disk (03) in the bevel gear wheel for housing (14) and a sliding disk (04) on top of
the first one.
2. Slide bearing bush for plain bearing (13) through the sliding disks into the bevel gear wheel for
housing (14).
3. Slide a sliding disk (04) and a sliding disk (03) on the bearing bush for plain bearing (13).
4.
NOTE
Incorrect clamping in the vise can cause threaded connections to become jammed and
deformed unintentionally!
The threaded connection cannot be screwed and may become damaged.
Screw a connection cover (01) into the housing (02).
Clamp the housing (02) in the vise.
5. Screw the bevel gear wheel for the housing (14) into the housing (02) and tighten it with a face
wrench.
6. Remove the screwed parts from the vise.
7. Unscrew the connection cover (01) from the housing (02) once again.
8. Clamp the shaft-axle connection (15) with preassembled parts (05, 06, 07, 08, 09, 17, 18) in the
vise.
9. Slide the rotor shaft with star wheel (12) into the housing (02) through the bearing bush for plain
bearing (13).
10.
NOTE
To ensure that the device functions securely, the position of the nozzles on the opposite
nozzle carriers with respect to one another must be observed!
Align the nozzles (08) the opposite nozzle carriers (18) perpendicular to one another so that the
axles of the nozzles (08) form a cross and are in horizontal/vertical position with respect to the
housing (02).
Screw the rotor shaft with star wheel (12) into the shaft-axle connection (15) and tighten with the
assembly tools for rotors.
11. To secure the connection against loosening, screw 1x threaded pin (19) into the shaft-axle
connection (15) and tighten it.
12. Screw and tighten the bypass plug (10) in the inflow disk (11).
13. Place the inflow disk (11) with the smooth surface facing downwards into the housing (02).
14. Check to see if the assembled nozzle fitting is rotating freely around the rotor shaft with star wheel (12).
15. Clamp the housing (02) into the vise again.
16. Screw the connection cover (01) into the housing (02) and tighten it.
Содержание TANKO JM100
Страница 10: ...Jet Cleaner TANKO JM VIII Translation of the original Operating Installation Instructions 2016 12 Contents...
Страница 100: ...Jet Cleaner TANKO JM 90 90 Translation of the original Operating Installation Instructions 2016 12 Appendices...
Страница 101: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group Notizen...
Страница 102: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...
Страница 103: ...Jet Cleaner TANKO JM A member of Neumo Ehrenberg Group...