AV6A 10
POWERLINK Diagnostic LEDs
LED
Status
Meaning
LS/DA 1
Error
Status
Green
Off
Green
Input connected to Ethernet, power OK,
node address ok, no Ethernet errors,
encoder operational
LS/DA 1
Status
Flashing
Green
Active inbound communication
LS/DA 2
Status
Green
Output connected to next encoder
LS/DA 2
Flashing
Green
Active communication to next encoder
Error
Red
Ethernet Error or invalid node address
Status
1 Flash
Pre-Operational Mode 1
2 Flashes Pre-Operational Mode 2
3 Flashes Ready to operate
Blinking
Stopped