APPENDIX 2 PUSH VIDEO CONFIGURATION
59
APPENDIX 2 PUSH VIDEO CONFIGURATION
Note:
This function is for selected models only.
A2.1 Alarm Sensor Connection
Connect the alarm sensor, such as magnetic contacts, to the alarm-in port on the rear panel. Alarm-in 1
corresponds to video channel 1, alarm-in 2 corresponds to video channel 2, and so on.
Note:
The voltage restriction for alarm-in device connection is under DC24V 1A.
Then, go to
MENU
PERIPHERAL
LOCAL ALARM IN
to choose how the alarm sensor works (
OFF
/
N.C.
/
N.O.
), and go to
MENU
CAMERA
DETECTION
to enable
MOTION
.
If the connected camera is our brand’s camera with alarm I/O support, you can also connect the alarm sensor to
the camera.
Note:
Please check the user manual of the camera to know voltage restriction for alarm-in device
connection.
Then, go to
MENU
CAMERA
DETECTION
and make sure:
1. MOTION is set to
ON
.
2.
ALARM
is configured (
N.C.
/
N.O.
) when an external alarm device is connected, or
INTERNAL ALARM
is set to
ON
when the connected camera has a PIR sensor built-in.
DETECTION
CHANNEL TITLE
ALARM
INTERNAL ALARM
SENSITIVITY
MOTION
AREA
ADVANCED CONFIG
CH1
OFF
ON EDIT
ON
EDIT
CH2
N.C.
OFF
EDIT ON
EDIT
CH3
N.O.
OFF
EDIT OFF
EDIT
CH4
OFF
OFF
EDIT OFF
EDIT
APPLY