984-0013-04
15
XII
SPECIFICATIONS
MECHANICAL
Size: 8 3/8”W X 14 1/8”H X 2 5/16”D
Weight: 9 lbs
ELECTRICAL
Phone line requirements: (TELCO) Standard (analog) loop start voice grade touch-tone telephone line,
PBX or key system station analog telephone line.
AC Power: (Transformer supplied)
120VAC to 16-18
VAC @ min. 1A
Battery: (Supplied)
Lead - Acid Battery - 12VDC @ min 1.3Ah
Phone line voltage:
on-hook 24 to 70VDC (nominally 48VDC)
Phone line voltage:
off-hook 8 to 20VDC (nominally 14VDC)
Ring Sensitivity:
40 - 120VAC RMS
Dialing:
DTMF (Dual Tone Multi Frequency)
Frequency Response:
550Hz - 3400Hz, +/- 3db.
Operational Loop impedance: 600 ohms
FCC Registration:
US: NFLTE02B33770
Ringer Equivalency Number:
0.2B