AVIRE Janus Call Director EMS5 Скачать руководство пользователя страница 10

      
 

984-0013-04 

 

7

 

 

 

  

  Note: Outgoing messages will start to play only on an outgoing call from an 

elevator port when the voice detection circuit of the EMS5 detects that the 
call has been answered and the call waiting beeping stops. 

 

  Note: Incoming messages will start to play only on an incoming call when 

the EMS5 is set up to answer incoming calls and after it plays the diddle-
diddle sound.
 

 
V

   Additional Programming Commands 

 
*1 A B C #  (Default *1 445 #) 

  A – The number of incoming rings before answers incoming call, [0-8], default 4 

Note: When A = 0, the EMS5 will not answer incoming calls from an outside line. 
(Operator) 

  B – The number of rings to ring the local port from a call initiated from an elevator 

port [0-8], default 4 (if the unit is programmed to call out it will do so after 
completing ringing)  

Note: When B = 0, the EMS5 will not Ring the Local Service Port when a call comes in 
from an elevator phone but instead the elevator phone will use the phone line to call out 
right away.  Also local service port will be connected to the phone line so if the master 
station goes off-hook it will hear dial-tone.  If there is no phone line connected to the 
EMS5 set “B” to 8 and delete all phone numbers by programming * 01 #, * 02 #, * 03 #.  
This will cause the Local Service Phone (or Master Station) to ring 3 times the number 
programmed into “B”. 

  C – The number of outgoing rings for each phone number [1-8], default 5 

 
*05 Phone Number for Low Battery Backup Call# 
Note: If the unit works off the battery and the battery voltage drops below 12VDC for 10 
minutes it will make a call to this number. 
Note: The Battery LED should also be blinking to indicate low voltage on battery. (Less 
then 12 volts for more then 10 minutes) 
 
**01 - Plays back the number as DTMFs 
**02 - Plays back the number as DTMFs 
**03 - Plays back the number as DTMFs 
**05 - Plays back the number as DTMFs 

 

*43 XXX # - Call Timer, Default XXX=240, range [060-990] 

 

*44 X # - AUX1 Phone line monitoring output, Default: *44 0 #. (X=0-1, 0=Disabled, 
1=Enabled) 
 
Note: If AUX1 is enabled it will close within 5 minutes after the phone line is 
disconnected from the unit and re-open within 5 minutes when the phone line is 

Содержание Janus Call Director EMS5

Страница 1: ... Master Station phone Enter 08601 you will hear three beeps Enter 03 number to dial you will hear three beeps Enter to exit programming For other programming options refer to manual Avire Inc 415 Oser Avenue Suite Q Hauppauge New York 11788 Phone 631 864 3699 Toll Free 800 527 9156 Fax 631 864 2631 Email sales us avire global com www avire global com www januselevator com Janus is a brand of Avire...

Страница 2: ...n Instructions Model No EMS5 Avire Inc 415 Oser Avenue Suite Q Hauppauge New York 11788 Phone 631 864 3699 Toll Free 800 527 9156 Fax 631 864 2631 Email sales us avire global com www avire global com www januselevator com Janus is a brand of Avire ...

Страница 3: ...984 0013 03 iii Wiring Diagram ...

Страница 4: ...AMMING THE EMS5 TO PLAY 6 VOICE MESSAGES V ADDITIONAL PROGRAMMING COMMANDS 7 VI EMS5 ONBOARD DISPLAY CODES 9 VII PROGRAMMING INSTRUCTIONS FOR 10 HANDSFREE PHONES CONNECTED TO EMS5 VIII OPERATING INSTRUCTIONS 10 IX OPERATING FAQ s 12 X TROUBLESHOOTING GUIDE 13 XI MOUNTING DIAGRAM 14 XII SPECIFICATIONS 15 XIII WARRANTY POLICY 16 XIV RETURN POLICY 16 XV FCC 16 ...

Страница 5: ...S5 s unit s 3 Wiring from the EMS5 s to Master Stations with Display Because the signaling between the EMS5 s and the Master Stations with displays is digital the digital signal noise WILL bleed over onto the pair coming from the Local Service port Add up the total length of wiring from Com Out to Com In on each EMS5 plus the total length of cabling required to all Master Stations with a Display a...

Страница 6: ...mary through the last or eighth secondary follow these steps a Any EMS5 can be switched between being a primary unit and a secondary unit by programming a simple programming command b Perform this step after the EMS5 is powered up If you have a secondary unit and need to make it a primary unit you can use the keypad or call into the unit to program it See accessing programming mode section on page...

Страница 7: ... ports labeled LOCAL SERVICE and COM OUT If you are planning to answer incoming calls in the building you will need the local service jack If you have more than one EMS5 you will need the COM OUT jack You will always need the COM OUT jack if you have a Master Station with the digital display 14 Using another modular cord plug one end into the COM OUT port on the first EMS5 and the other end into t...

Страница 8: ... the programming instructions below Method 3 Press the Program above the onboard keypad If you have multiple EMS5 units press the Program button on the first Master EMS5 unit of the group Follow the programming instructions below You don t need to enter the pass code 08601 PROGRAMMING THE EMS5 s TO DIAL ON A STANDARD PHONE LINE The EMS5 can dial up to three different phone numbers Wait for three b...

Страница 9: ...en the unit is about to timeout This message is pre recorded at the factory but can be changed as needed The fourth and last message can be setup to play on an outgoing low battery backup call Follow the programming instructions below to setup the EMS5 to play messages You must first access programming mode described on section 3 of Programming instructions Then use any of the following commands 9...

Страница 10: ...ll out right away Also local service port will be connected to the phone line so if the master station goes off hook it will hear dial tone If there is no phone line connected to the EMS5 set B to 8 and delete all phone numbers by programming 01 02 03 This will cause the Local Service Phone or Master Station to ring 3 times the number programmed into B C The number of outgoing rings for each phone...

Страница 11: ...is answered by the operator on tone or voice mode and the call is acknowledged 6 X Set Unit ID to X value 0 7 Note The ID will set the Display to show different numbers as shown below ID 0 01 08 ID 1 09 16 ID 2 17 24 ID 3 25 32 ID 4 33 40 ID 5 41 48 ID 6 49 56 ID 7 57 64 7 2 1 Enable CPC detection Default 7 2 0 Disable CPC detection 75 1 Enable Automatic Rollover for Force Thru Calling When enable...

Страница 12: ...lt 891 Note The Outgoing message could be stopped by using any DTMF tone if it s set to 2 or 3 repetitions The EMS5 GIVES YOU 6 beeps exits programming and goes back on hook 90 CODE TO SET THE FOLLOWING CODES TO FACTORY DEFAULTS 1 445 20 30 43 240 44 0 5 000 70 2 72 1 75 0 8 0 87 1 88 1 89 1 VI EMS5 ONBOARD DISPLAY CODES When EMS5 first powers up it should scroll on the Display the following EMS5 ...

Страница 13: ... 4 Enter the programming pass code for the elevator phone It will be 94851 or 9000000 listen for three beeps 5 Disable the first number by entering 0 listen for three beeps 6 Disable the second number dialer by entering 1 listen for three beeps 7 If the EMS5 is not connected to a phone line then enter the following code to disable the voice message 1180180 The voice message is used by an off site ...

Страница 14: ...or phone again The operator will hear an audible diddle diddle diddle sound which means that someone is in the elevator This feature is for passengers who cannot speak or has difficulty doing so 7 At the end of the call the operator simply hangs up Note If more than one elevator phone is calling out the EMS5 will transmit the typical call waiting tones to the operator so he she knows there is anot...

Страница 15: ... At the end of the call hang up the handset to terminate the call IX OPERATING FAQ s QUESTION What will happen if multiple phones on an EMS5 call director try to place a call ANSWER When multiple phones on the out ports of the EMS5 unit are trying to call out all the phones will be allowed to complete their call either locally to the local service port or to an outside line in an order of first co...

Страница 16: ...ct If the operator presses a 3 the timer will be renewed for the time that it was set for X TROUBLESHOOTING GUIDE IF THE HANDS FREE PHONE IS NOT PLACING THE CALL 1 CHECK THE PUSH BUTTON AND CONNECTIONS TO THE PHONE ARE THE CONNECTIONS AND BUTTON GOOD YES PROCEED TO STEP NO 2 NO REPLACE AND OR REPAIR RETRY THE PHONE 2 CONNECT A HANDSET PHONE TO THE MODULAR JACK ON THE HANDS FREE PHONE BOARD AND TRY...

Страница 17: ...984 0013 04 14 XI MOUNTING DIAGRAM Diagram not drawn to scale ...

Страница 18: ...lephone line AC Power Transformer supplied 120VAC to 16 18VAC min 1A Battery Supplied Lead Acid Battery 12VDC min 1 3Ah Phone line voltage on hook 24 to 70VDC nominally 48VDC Phone line voltage off hook 8 to 20VDC nominally 14VDC Ring Sensitivity 40 120VAC RMS Dialing DTMF Dual Tone Multi Frequency Frequency Response 550Hz 3400Hz 3db Operational Loop impedance 600 ohms FCC Registration US NFLTE02B...

Страница 19: ...or this equipment If requested this number must be provided to the telephone company The REN is used to determine the number of devices that may be connected to a telephone line Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may ...

Отзывы: