background image

13

Description of
Operations Menu

Following are descriptions of the various options in the Operations Menu. The

indentations represent levels within the menu.

G.T.N.

Accesses inbound/outbound functions (Method 1).

Report

Prints the group assigned to this function.

Edit

Allows viewing/editing of channel information. When the edit

parameter is sealed, values may be viewed only, not edited (refer

to the Service Manual).

XXX

The current channel is displayed as the default. Scroll through

the existing channels by using the MENU (forward) and 

(backward) keys.

Inbound

Displays inbound value. None will be displayed if an

inbound weight does not exist. Press "0" and ENTER

to clear the inbound weight.

Hour In

Displays time of inbound weight. This parameter is

only offered if an inbound weight already exists.

Day In

Displays date of inbound weight.  This parameter is

only offered if an inbound weight already exists.

Total

The net accumulator value for the selected channel.

Counter

The transaction counter for the selected channel.

Delete

Allows user to clear the  channel database. If the database is

already clear, dOnE will be displayed and the remaining

parameters will not appear.

Done

Offered only if the database is empty.

No

Will not delete the channels. Not offered if database is empty.

One

Allows user to select a specific channel to delete. Not offered if

the database is empty.

All

Allows user to delete all channels at one time. Not offered if

database is empty.

TARES

Accesses multiple tare registers (Method 2)

Report

Prints the group assigned to this function.

Edit

Allows viewing/editing of channel information.

XXX

The current tare register is displayed as the default. Scroll

through the existing registers by using the MENU (forward) and

 (backward) keys.

Tare

Displays the current tare value.

Type

Displays the type of tare. Pb indicates a pushbutton

tare entered by using the TARE key. EntErEd

indicates a tare that was entered through the keypad.

Total

The net accumulator value for the selected register.

Counter The transaction counter for the selected register.

Clear

Allows user to clear the accumulators and transaction counters

for the tare registers. Not offered if the database is empty.

No

Will not clear the accumulators and counters.

All

Clears the accumulators and counters for all tare registers but

leaves the tare values intact.

Содержание WI-127

Страница 1: ...WI 127 Inbound Outbound User s Manual...

Страница 2: ...674 0012e1 Printed in USA Risk of electrical shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Weigh Tronix reserves the right to change specifi...

Страница 3: ...g and or Editing Tare Register Values 6 Clearing Deactivating Tare Register Values 7 Editing and Deleting Tare Registers 7 Net Weighing 7 Printing a Report 7 Using Cutoff Registers 8 Viewing Cutoffs 8...

Страница 4: ...keys 0 9 Operational annunciators Gross Tare Net Print Zero Motion Under Accept Over Cutoff ID Three units of measure Display Eight digit seven segment 0 8 inch high LED Display rate Selectable 1 2 5...

Страница 5: ...me of the first weighing operation and the second The indicator will keep track of the number of transactions and accumulate the totals for each inbound outbound channel Method 2 Using Multiple Tare R...

Страница 6: ...and return to weigh mode from within any menu TARE Enters a pushbutton tare in the display mode Can be configured to accept values through the numeric keypad PRINT Used to initiate manual data transm...

Страница 7: ...g any changes ENTER Used to end digit entry accept a change made or select an item from a function list Backspaces deletes the last digit or punctuation mark entered while in numeric entry and moves l...

Страница 8: ...a new channel or call up a previously entered one or 2b Use the MENU forward and backward keys to select a previously entered channel The channel number is displayed 3 With weight on the scale press E...

Страница 9: ...t of the GTN database information for each channel 4 To return to weight display mode press SELECT Sample Inbound Outbound Report You may delete any or all of the channels in your WI 127 To do so you...

Страница 10: ...in the register number using the keypad or use the MENU forward and backward keys to select a tare register The tare register number is displayed 3 Press ENTER The tare value in that register is displ...

Страница 11: ...he desired tare register number using the keypad Tare register number is displayed 2 Press TARE REGISTER Tare value is displayed in net mode 3 Place weight on the scale Net weight is displayed 4 Press...

Страница 12: ...cutoff register you wish to view press the number of that register then press CUTOFF That particular cutoff register is displayed You may scroll through the remaining registers by pressing the CUTOFF...

Страница 13: ...the over and under values must be set as tolerances For example if target 100 over might 10 and under might 10 This means that any weight between 90 and 110 lbs is acceptable 1 Press MENU until bound...

Страница 14: ...ime is entered press ENTER to accept the new time To set the 24 hour clock a Key in time as hh mm ss b After the correct time is entered press ENTER to accept the new time 5 Press ENTER to view the ne...

Страница 15: ...e ID number may be up to 8 digits in length It may include any combination of the numbers 0 through 9 dashes and one decimal point 1 From display mode press MENU until id is displayed 2 Press ENTER Th...

Страница 16: ...ing functions in the Operations Menu These parameters can be viewed and changed if allowed This manual assumes the unit is configured to allow full access to these functions To enter the Operations Me...

Страница 17: ...f the database is already clear dOnE will be displayed and the remaining parameters will not appear Done Offered only if the database is empty No Will not delete the channels Not offered if database i...

Страница 18: ...ase is empty All Allows user to delete all tare registers at one time Not offered if database is empty HOUR Allows the user to set the time DAY Allows the user to set the date ID Allows the user to se...

Страница 19: ...n the PRINT key is pressed while using a tare register a printout is performed which includes time date the tare register number and gross tare and net weights The tare weight includes the type of tar...

Страница 20: ...when attempting to modify a sealed selection without edit privileges Displayed while waiting for a stable valid weight to use as a zero reference on power up Displayed when input voltage to excitatio...