9
Setting Target and
Over/Under Values
Checkweighing
The WI-127 is configured to perform checkweighing functions. The checkweighing
parameters are accessed through the Operations Menu shown in Figure 2.
The target value must be considered when determining values to enter for over
and under. Depending on the target values, the over/under values can be entered
as either actual weight values or as tolerance values.
If the target value is zero, you may enter over and under values as actual weight.
For example, if the target = 0, over might = 100 lbs, and under might = 50 lbs.
This means that any weight between 50 lbs and 100 lbs is acceptable. (Note: The
ACCEPT annunciator does not illuminate when target = 0.)
If the target value is a value other than zero, the over and under values must be
set as tolerances. For example, if target = 100, over might = 10, and under
might = -10. This means that any weight between 90 and 110 lbs is acceptable.
1.
Press MENU until. . .
boundS is displayed.
2.
Press ENTER . . .
OVEr is displayed.
3.
Press ENTER. . .
The over tolerance is displayed and the
OVER annunciator illuminates.
4.
Using the keypad, enter the new
over tolerance value. . .
New value is displayed.
5.
Press ENTER. . .
OVEr is displayed.
6.
Press MENU. . .
UndEr is displayed.
7.
Press ENTER. . .
The under tolerance is displayed and
the UNDER annunciator illuminates.
8.
Enter the new under tolerance
value. . .
New value is displayed.
9.
Press ENTER. . .
UndEr is displayed.
10. Press MENU. . .
tArgEt is displayed.
11. Press ENTER. . .
The target value is displayed and the
ACCEPT annunciator illuminates.
12. Enter the new target value. . .
New value is displayed.
13. Press ENTER. . .
tArgEt is redisplayed.
14. After entering all new values,
press SELECT. . .
Indicator returns to display mode.
Содержание WI-127