16
Error Messages
The following are displays you may see if problems occur or if invalid operations
are attempted with your WI-127:
Display
Description
Overrange weight.
Underrange weight.
Recovering from lock-up or out of range condition.
A-D converter is not functioning.
A-D converter subjected to an input signal beyond ±5.00000 mV/V
The unit cannot perform a function. Displayed only while key is held
down.
Corrupted data in the reset menus. See the Service Manual. (*
= RESET, SETUP, or CAL)
Displayed while a key is pressed when attempting to modify a sealed
selection without edit privileges.
Displayed while waiting for a stable, valid weight to use as a zero
reference on power-up.
Displayed when input voltage to excitation regulator drops below
10.5 VDC. Will clear when input voltage rises above 11.5 VDC.
Displayed when the ready/busy handshake has exceeded its time out
limit. Default is 2 seconds. This can also apply to optional 2nd and
3rd serial ports.
Displayed when the net accumulator exceeds its maximum value.
Message will appear when trying to view the accumulator total.
Displayed if the tare register value does not exist and the memory is
full. Displayed only while key is held down.
O. LoAd
L.C. Error
Auto. 0
1 Busy
too big
full