8
Cutoff Registers
The standard WI-127 includes three cutoffs. Adding the optional cutoff card raises
this number to ten.
When activated (weight on the scale is less than the weight in the cutoff registers),
these cutoffs are all on at the same time. Each cutoff will deactivate as soon as the
weight on the scale matches the value in each cutoff register.
Cutoffs may be positive or negative values.
Cutoff registers may be viewed by two methods:
Method A:
1.
Press the CUTOFF key. . .
1 xx is displayed. The number 1
stands for cutoff register #1 and xx is
the current value in register 1.
2.
Continue pressing CUTOFF or
MENU to scroll forward or
!
!
!
!
!
to
scroll backward through the
remaining cutoff registers.
Method B:
If you know which cutoff register you
wish to view, press the number of that
register, then press CUTOFF. That particular
cutoff register is displayed. You may
scroll through the remaining registers by
pressing the CUTOFF key consecutively.
To enter a cutoff value,
1.
Press CUTOFF until the cutoff
register you wish to set is displayed.
3 0 (for example).
2.
Enter the cutoff value in one of two
ways:
2A. Key in the correct cutoff value
using the keypad . . .
3 xx is displayed.
or
2B. With active weight on the scale,
press TARE . . .
The active weight is set as the cutoff
value.
3.
Press MENU or CUTOFF to
accept the value and move to the
next cutoff register.
4.
To return to weight display mode,
press SELECT.
To deactivate or clear a cutoff value,
set the value to zero.
Viewing cutoffs
Entering cutoff values
Press ENTER at any time to exit
the cutoff register menu.
Press ENTER at any time to exit
the cutoff register menu.
Clearing/deactivating
cutoff values
Содержание WI-127
Страница 1: ...WI 127 Inbound Outbound User s Manual...