1
Introduction
The WI-127 Inbound/Outbound is a microprocessor-driven weight indicator
designed to interface with an electronic scale. Its purpose is to calculate net weight
value and to transmit serially that value, along with other weighing information, to
a printer, computer, or programmable controller.
A hallmark of the WI-127 Inbound/Outbound indicator is its versatility in adapting
to a broad range of weighing applications requiring calculation of net value.
Two methods of net weighing are available:
Method 1: Inbound/Outbound Weighing allows you to live-weigh an empty or full
container (or vehicle, etc.), with or without transmission of data. Later you
may live-weigh the same container for calculation of a net value and trans-
mission of data. The indicator will select the larger weight as the gross
weight and always transmit a positive net weight. The first weighing of the
container stores its value in memory so that similar weighing operations can
continue in up to 300 other channels between the time of the first weighing
operation and the second. The indicator will keep track of the number of
transactions and accumulate the totals for each inbound/outbound channel.
Method 2: Using Multiple Tare Registers allows you to store tares in two
different ways. You may:
• Live-weigh an empty container and store its tare value in one of 300 tare
registers. Then do multiple live weighings with the same refilled container or
with containers of equal tare weight value. The WI-127 Inbound/Outbound
Indicator will use the tare value you stored in memory for calculation of net
value and transmission of data.
• Enter using the keypad a predetermined weight value in one of 300 tare
registers. Then do multiple live weighings with filled containers equal in
weight to the memory-stored value for calculation of net value and transmis-
sion of data.
The indicator will also keep track of the number of transactions and accumu-
late the totals for each tare register.
Operations mode contains all normal weighing operations. In this mode you can
view or set the following parameters:
• inbound/outbound channels
• multiple tare registers
• cutoff registers
• target, over and under values
• time
• date
• identification number
Operations Mode