18

Loadcell —

Displays the factory normalized loadcell input. With LOAdCELL

displayed, press ENTER to view the counts. Press UNITS to

toggle between the counts display mode and mV/V display mode.

Span is 200,000 counts per millivolt per volt. Press ESCAPE to

return to LOAdCELL.

Serial 

Allows testing of the internal serial ports. With SEriAL          dis-

played, press ENTER to select the port to test. Port 1 is always

the internal serial port. (Port 2 and 3 are only offered if extra

serial ports are installed.) Press ENTER again to view ready/

busy. Then press MENU to view loop/no loop. Press ESCAPE

to return to SEriAL.

Outputs —

Allows testing of the outputs. With OutPutS displayed, press

ENTER twice to cycle through the available outputs in sequen-

tial order. Press ESCAPESEqUEnCE is displayed. Press

MENU to view the available outputs. Press ENTER to view the

status of the outputs. The outputs are numbered left to right,

starting with one. A "1" indicates the output is activated; a "0"

indicates the output is deactivated. To change the status of the

ouput, move the decimal point to the right of the output you

wish to change. Toggle the status by pressing ENTER. If the

optional I/O board is installed, an additional eight outputs are

available under Out. 9-16. Press ESCAPE to return to

OutPutS.

Inputs —

Allows testing of the inputs. With InPutS displayed, press

ENTERStAndArd is displayed. Press ENTER again to view

the status of each input. The inputs are ordered 1-8 from left to

right. A "1" indicates the input is activated; a "0" indicates the

input is deactivated.  If the optional I/O board is installed, an

additional eight inputs are available under OPtion. Press ES-

CAPE twice to return to InPutS.

Voltages —

Allows testing of the power supply voltages. With VoltAGES

displayed, press ENTER to test the unregulated loadcell

excitation power supply voltage (13 volts). Press MENU

repeatedly to scroll through the remaining power voltages:

the -5 volt excitation voltage (-5 volts), the unregulated 5 volt

logic supply voltage (10 volts), and the relay supply voltage (24

volts). Press ESCAPE to return to VoltAGES.

Содержание WI-127

Страница 1: ...WI 127 Inbound Outbound User s Manual...

Страница 2: ...674 0012e1 Printed in USA Risk of electrical shock Do not remove cover No user serviceable parts inside Refer servicing to qualified service personnel Weigh Tronix reserves the right to change specifi...

Страница 3: ...g and or Editing Tare Register Values 6 Clearing Deactivating Tare Register Values 7 Editing and Deleting Tare Registers 7 Net Weighing 7 Printing a Report 7 Using Cutoff Registers 8 Viewing Cutoffs 8...

Страница 4: ...keys 0 9 Operational annunciators Gross Tare Net Print Zero Motion Under Accept Over Cutoff ID Three units of measure Display Eight digit seven segment 0 8 inch high LED Display rate Selectable 1 2 5...

Страница 5: ...me of the first weighing operation and the second The indicator will keep track of the number of transactions and accumulate the totals for each inbound outbound channel Method 2 Using Multiple Tare R...

Страница 6: ...and return to weigh mode from within any menu TARE Enters a pushbutton tare in the display mode Can be configured to accept values through the numeric keypad PRINT Used to initiate manual data transm...

Страница 7: ...g any changes ENTER Used to end digit entry accept a change made or select an item from a function list Backspaces deletes the last digit or punctuation mark entered while in numeric entry and moves l...

Страница 8: ...a new channel or call up a previously entered one or 2b Use the MENU forward and backward keys to select a previously entered channel The channel number is displayed 3 With weight on the scale press E...

Страница 9: ...t of the GTN database information for each channel 4 To return to weight display mode press SELECT Sample Inbound Outbound Report You may delete any or all of the channels in your WI 127 To do so you...

Страница 10: ...in the register number using the keypad or use the MENU forward and backward keys to select a tare register The tare register number is displayed 3 Press ENTER The tare value in that register is displ...

Страница 11: ...he desired tare register number using the keypad Tare register number is displayed 2 Press TARE REGISTER Tare value is displayed in net mode 3 Place weight on the scale Net weight is displayed 4 Press...

Страница 12: ...cutoff register you wish to view press the number of that register then press CUTOFF That particular cutoff register is displayed You may scroll through the remaining registers by pressing the CUTOFF...

Страница 13: ...the over and under values must be set as tolerances For example if target 100 over might 10 and under might 10 This means that any weight between 90 and 110 lbs is acceptable 1 Press MENU until bound...

Страница 14: ...ime is entered press ENTER to accept the new time To set the 24 hour clock a Key in time as hh mm ss b After the correct time is entered press ENTER to accept the new time 5 Press ENTER to view the ne...

Страница 15: ...e ID number may be up to 8 digits in length It may include any combination of the numbers 0 through 9 dashes and one decimal point 1 From display mode press MENU until id is displayed 2 Press ENTER Th...

Страница 16: ...ing functions in the Operations Menu These parameters can be viewed and changed if allowed This manual assumes the unit is configured to allow full access to these functions To enter the Operations Me...

Страница 17: ...f the database is already clear dOnE will be displayed and the remaining parameters will not appear Done Offered only if the database is empty No Will not delete the channels Not offered if database i...

Страница 18: ...ase is empty All Allows user to delete all tare registers at one time Not offered if database is empty HOUR Allows the user to set the time DAY Allows the user to set the date ID Allows the user to se...

Страница 19: ...n the PRINT key is pressed while using a tare register a printout is performed which includes time date the tare register number and gross tare and net weights The tare weight includes the type of tar...

Страница 20: ...when attempting to modify a sealed selection without edit privileges Displayed while waiting for a stable valid weight to use as a zero reference on power up Displayed when input voltage to excitatio...

Страница 21: ...appear on the display as it is pressed After testing the buttons press MENU A to D Performs A to D test to check the raw offset and gain of the electronics With A to d displayed press ENTER to view th...

Страница 22: ...s the output is activated a 0 indicates the output is deactivated To change the status of the ouput move the decimal point to the right of the output you wish to change Toggle the status by pressing E...

Страница 23: ...ont MN 56031 USA Telephone 507 238 4461 Facsimile 507 238 4195 e mail industrial weigh tronix com www weigh tronix com 217 Brunswick Blvd Pointe Claire QC H9R 4R7 Canada Telephone 514 695 0380 Facsimi...

Отзывы: