AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF
11
Model
Indoor Unit
ALCA-H24/4R1AA
ALCA-H36/5R1AA
Panel
MB12
MB12
Outdoor Unit
AL-H24/4R1D(U)
AL-H36/5R1D(U)
Factory Model
Indoor Unit
ALCa-H24B4/R1EB-B7
ALCa-H36A5/R1EB-B7
Panel
MB12
MB12
Outdoor Unit
AL-H24A4/R1(T)-B7
AL-H36A5/R1(T)-B7
Code
Indoor Unit
16106022000053
16106022000056
Panel
16108002000007
16108002000007
Outdoor Unit
16107022000018
16107022000020
Power Supply
V~,Hz,Ph
220~240,50,1
380~415,50,3
Capacity
Cooling
Btu/h
24000
36000
kW
7.20
10.60
Heating
Btu/h
27500
40000
kW
8.08
11.70
Electric Data
Rated Cooling Power
Input
kW
2.39
3.77
Rated Heating Power
Input
kW
2.50
3.50
Rated Cooling Current
A
11.06
6.76
Rated Heating Current
A
11.59
6.28
Performance
EER
W/W
3.01
2.81
COP
W/W
3.23
3.34
Indoor Fan Motor
Model
XD30A
YDK45-6Q
Brand
WELLING/Sinjun
WELLING/Sinjun
Output Power x Fan
Quantity
W
30*1
45*1
Capacitor
uF
2.5
3
Speed (Hi/Mi/Lo)
r/min
500/430/320
650/520/450
Indoor Coil
Number Of Rows
2
2
Tube Pitch(a)x Row
Pitch(b)
mm
20.5×12.7
20.5×12.7
Fin Pitch
mm
1.4
1.4
Fin Material
Hydrophilic aluminum fin
Tube Outside Dia.and
Type
mm
φ7
,
Inner grooved
φ7
,
Inner grooved
Coil Length x Height x
Width
mm
2142×205×25.4
2142×205×25.4
Heat Exchanging Area
m
2
11.34
12.76
Indoor Unit
Indoor Air Flow
(Hi/Mi/Lo)
m
3
/h
1300/1040/910
1500/1200/1050
Noise Level(Hi/Mi/Lo)
dB(A)
45/42/36
48/45/39
Net Dimension
mm
835×835×250
835×835×250
Содержание AL-H12/4R1D
Страница 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Страница 70: ...AUX Light CAC 50Hz R410A Universal outdoor unit 70 5 Electrical wiring and connection ALMD H18 4R1D ...
Страница 71: ...AUX Light CAC 50Hz R410A Universal outdoor unit 71 ALMD H24 4R1D ALMD H36 5R1D ALMD H48 5R1D ALMD H60 5R1D ...
Страница 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Страница 73: ...AUX Light CAC 50Hz R410A Universal outdoor unit 73 ALMD H36 4R1 ALCA H36 5R1D ALCA H48 5R1D ALCA H60 5R1D ...
Страница 91: ...AUX Light CAC 50Hz R410A Trouble shooting 91 3 Dimension AL H12 4R1D U AL H18 4R1D U AL H24 4R1D U ...
Страница 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Страница 97: ...AUX Light CAC 50Hz R410A Trouble shooting 97 AL H36 4R1 U AL H36 5R1D U AL H48 5R1D U AL H60 5R1D U ...
Страница 127: ...AUX Light CAC 50Hz R410A Trouble shooting 127 7 Failure analysis Wired controller communication failure ...
Страница 128: ...AUX Light CAC 50Hz R410A Trouble shooting 128 Communication failure between indoor and outdoor unit ...
Страница 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Страница 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Страница 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Страница 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Страница 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Страница 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Страница 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Страница 136: ...AUX Light CAC 50Hz R410A Trouble shooting 136 Refrigerant shortage or four way valve failure protection ...
Страница 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Страница 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Страница 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Страница 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Страница 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Страница 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Страница 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Страница 144: ...AUX Light CAC 50Hz R410A Trouble shooting 144 Air switch action when air conditioner starting up ...
Страница 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...