AUX-Light CAC 50Hz R410A
Trouble shooting
84
1. Specfication
Model
AL-H12/4R1D(U)
AL-H18/4R1D(U)
AL-H24/4R1D(U)
Factory Model
AL-H12A4/R1(T)-B
7
AL-H18A4/R1(T)-B7
AL-H24A4/R1(T)-B7
Code
16107022000017
16107022000019
16107022000018
Power Supply
V~,Hz
,Ph
220~240,50,1
220~240,50,1
220~240,50,1
Max. Input Consumption
W
1750
2700
3200
Max. Current
A
7.76
12.10
17.80
Capacity
Cooling
Btu/h
12000
18000
24000
kW
3.52
5.28
7.20
Heating
Btu/h
13500
20000
27569
kW
3.90
5.80
8.08
Compressor
Model
ASL150UV-C7LU
ASL201UV-C7EQ
ASH286UV-C8DU
Type
Rotary
Rotary
Rotary
Brand
HIGHLY
HIGHLY
HIGHLY
Capacity
W
3555
4900
6980
Input
W
1200
1633
2320
Rated Current(RLA)
A
5.55
7.65
10.9
Locked Rotor Amp(LRA)
A
30
38
60
Thermal Protection temp.
150
150
160
Capacitor
uF
35
50
70
Refrigerant Oil
ml
450
480
570
Outdoor
Fan Motor
Model
YDK31-6F
YDK31-6F
YDK68-6A
Brand
Tongdeli
Tongdeli
Sinjun
Output Power x Fan Quantity
W
31×1
31×1
68×1
Capacitor
uF
2.5
2.5
4
Speed
r/min
900
900
880
Coil
Number Of Rows
1
2
2
Tube Pitch(a)x Row Pitch(b)
mm
22×19.05
22×19.05
22×19.05
Fin Pitch
mm
1.4
1.4
1.5
Fin Material
Hydrophilic aluminum fin
Tube Outside Dia.and Type
mm
φ7
,
Inner grooved
φ7
,
Inner grooved
φ7
,
Inner grooved
Coil Length x Height x Width
mm
853×506×19.05
853×506×38.1
763×616×38.1
Heat Exchanging Area
m
2
10.47
15.99
22.10
Air Flow Volume
CFM
1471
1471
1648
m
3
/h
2500
2500
2750
Noise Level
dB(A)
53
55
60
Dimension
(W×D×H)
Net
mm
800×286×530
800×286×530
822×302×655
Packing
mm
920×400×620
920×400×620
945×430×725
Weight
Net
kg
37
40
50
Gross
kg
40
43
54
Refrigerant
Type
R410A
R410A
R410A
Содержание AL-H12/4R1D
Страница 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Страница 70: ...AUX Light CAC 50Hz R410A Universal outdoor unit 70 5 Electrical wiring and connection ALMD H18 4R1D ...
Страница 71: ...AUX Light CAC 50Hz R410A Universal outdoor unit 71 ALMD H24 4R1D ALMD H36 5R1D ALMD H48 5R1D ALMD H60 5R1D ...
Страница 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Страница 73: ...AUX Light CAC 50Hz R410A Universal outdoor unit 73 ALMD H36 4R1 ALCA H36 5R1D ALCA H48 5R1D ALCA H60 5R1D ...
Страница 91: ...AUX Light CAC 50Hz R410A Trouble shooting 91 3 Dimension AL H12 4R1D U AL H18 4R1D U AL H24 4R1D U ...
Страница 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Страница 97: ...AUX Light CAC 50Hz R410A Trouble shooting 97 AL H36 4R1 U AL H36 5R1D U AL H48 5R1D U AL H60 5R1D U ...
Страница 127: ...AUX Light CAC 50Hz R410A Trouble shooting 127 7 Failure analysis Wired controller communication failure ...
Страница 128: ...AUX Light CAC 50Hz R410A Trouble shooting 128 Communication failure between indoor and outdoor unit ...
Страница 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Страница 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Страница 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Страница 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Страница 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Страница 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Страница 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Страница 136: ...AUX Light CAC 50Hz R410A Trouble shooting 136 Refrigerant shortage or four way valve failure protection ...
Страница 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Страница 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Страница 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Страница 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Страница 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Страница 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Страница 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Страница 144: ...AUX Light CAC 50Hz R410A Trouble shooting 144 Air switch action when air conditioner starting up ...
Страница 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...