AUX Light Commercial Air Conditioners T1,50Hz, R410a,ON/OFF
56
16
直流电机
FP90A-ZL(
长短轴
)
Moter
1
17
ALCe-H24B4/C5
左挂架
Left suspend plate
1
18
ALCe-H24B4/C5
左侧板组件
Left side panel assembly
1
19
ALCe-H24A4/R1DCC5-B6
背板
组件
Chassis welding assembly
1
20
联轴器
φ15
Motor coupling
1
21
加长轴
φ15×565
Motor lengthen axes
1
22
ALCe-H24B4/C5
右侧板组件
Right side panel assembly
1
23
ALCe-H24B4/C5
右挂架
Right suspend plate
1
24
ALCe-H24B4/C5
右盖板
The Right side covers
1
25
ALCe-H24B4/C5
右泡沫
(
开模
)
Right foam
1
26.1
CJ
控制板
DCZ-OXNX-SN1T1(18-60)K-SY
E
PCB board
1
26.2
CJ
控制板
DCZ-OXNX-SNPOWER-C-SYE
PCB board
1
27
DR-120N/DC5-A
电控盒
The electronic control box
1
28
ALCe-H24B4/C5
中滤网
Filter In the center
1
29
ALCe-H24B4/C5
中格栅
Air-inlet grill
1
30
ALCe-H24B4/C5
滤网
Air-inlet filter
2
31
ALCe-H24B4/C5
格栅
Air-inlet grill
2
32
ALCe-H24B4/C5
显示盒组件
Display board cover
1
33
(ROHS)
步进电机
35BYJ46-QC50
Step motor
1
34
步进电机
35BYJ46-QC120
Step motor
1
Содержание AL-H12/4R1D
Страница 4: ...AUX Light Commercial Air Conditioners T1 50Hz R410a ON OFF 4 1 Nomenclature ...
Страница 70: ...AUX Light CAC 50Hz R410A Universal outdoor unit 70 5 Electrical wiring and connection ALMD H18 4R1D ...
Страница 71: ...AUX Light CAC 50Hz R410A Universal outdoor unit 71 ALMD H24 4R1D ALMD H36 5R1D ALMD H48 5R1D ALMD H60 5R1D ...
Страница 72: ...AUX Light CAC 50Hz R410A Universal outdoor unit 72 ALMD H18 4R1D ALMD H24 4R1D ...
Страница 73: ...AUX Light CAC 50Hz R410A Universal outdoor unit 73 ALMD H36 4R1 ALCA H36 5R1D ALCA H48 5R1D ALCA H60 5R1D ...
Страница 91: ...AUX Light CAC 50Hz R410A Trouble shooting 91 3 Dimension AL H12 4R1D U AL H18 4R1D U AL H24 4R1D U ...
Страница 93: ...AUX Light CAC 50Hz R410A Trouble shooting 93 1366 610 160 438 368 388 940 ...
Страница 97: ...AUX Light CAC 50Hz R410A Trouble shooting 97 AL H36 4R1 U AL H36 5R1D U AL H48 5R1D U AL H60 5R1D U ...
Страница 127: ...AUX Light CAC 50Hz R410A Trouble shooting 127 7 Failure analysis Wired controller communication failure ...
Страница 128: ...AUX Light CAC 50Hz R410A Trouble shooting 128 Communication failure between indoor and outdoor unit ...
Страница 129: ...AUX Light CAC 50Hz R410A Trouble shooting 129 Outdoor protection phase sequence ...
Страница 130: ...AUX Light CAC 50Hz R410A Trouble shooting 130 Cooling high pressure protection ...
Страница 131: ...AUX Light CAC 50Hz R410A Trouble shooting 131 Heating high pressure protection ...
Страница 132: ...AUX Light CAC 50Hz R410A Trouble shooting 132 Cooling low pressure protection ...
Страница 133: ...AUX Light CAC 50Hz R410A Trouble shooting 133 Heating low pressure protection ...
Страница 134: ...AUX Light CAC 50Hz R410A Trouble shooting 134 Cooling exhaust temperature protection ...
Страница 135: ...AUX Light CAC 50Hz R410A Trouble shooting 135 Heating exhaust temperature protection ...
Страница 136: ...AUX Light CAC 50Hz R410A Trouble shooting 136 Refrigerant shortage or four way valve failure protection ...
Страница 137: ...AUX Light CAC 50Hz R410A Trouble shooting 137 Sensor failure protection ...
Страница 138: ...AUX Light CAC 50Hz R410A Trouble shooting 138 No action after power on ...
Страница 139: ...AUX Light CAC 50Hz R410A Trouble shooting 139 Poor effect ...
Страница 140: ...AUX Light CAC 50Hz R410A Trouble shooting 140 ...
Страница 141: ...AUX Light CAC 50Hz R410A Trouble shooting 141 Abnormal sound or viberation ...
Страница 142: ...AUX Light CAC 50Hz R410A Trouble shooting 142 ...
Страница 143: ...AUX Light CAC 50Hz R410A Trouble shooting 143 Abnormal odor ...
Страница 144: ...AUX Light CAC 50Hz R410A Trouble shooting 144 Air switch action when air conditioner starting up ...
Страница 145: ...AUX Light CAC 50Hz R410A Trouble shooting 145 Air conditioner water leakage ...