9
unblocking of the heater is impossible, the indicators flash five times alternatively.
Pay attention
: when you apply unblocking function for the first time, RCP
remembers VIN code of the car. In the future unblock function will work only for
this car.
Settings Table (4)
1.
Boost
Heat Mode
Control
1.1.
Additional
engine heating in
boost heat mode
1.1.1
*Enabled by the module. Active level
on X1.6 disables the boost heat mode
1.1.2
Disabled by the module. Active level
on X1.6 enables the boost heat mode
1.1.3
Disabled by the module permanently
1.1.4
Disabled all the time, except in case
when the heater has operated before the
engine start
1.2.
Additional
engine heating
disable by coolant
temperature (in
Celsius degrees)
1.2.1
*Not applied
1.2.2
Higher than 0 degrees
1.2.3
Higher than +10 degrees
1.2.4
Higher than +20 degrees
1.2.5
Higher than +30 degrees
1.2.6
Higher than +40 degrees
1.2.7
Higher than +50 degrees
1.2.8
Higher than +60 degrees
1.2.9
Higher than +65 degrees
1.2.10
Higher than +70 degrees
2.
Heater
Timing
2.1.
Limitation of
heater total
operation time in
pre-heat mode
2.1.1
Not adjusted
2.1.2
40 minutes
2.1.3
50 minutes
2.1.4
60 minutes
2.1.5
*
70 minutes
2.1.6
80 minutes
2.1.7
90 minutes
2.1.8
100 minutes
2.1.9
120 minutes
2.2.
Limitation of
heater cycle
operation time in
pre-heat mode
2.2.1
10 minutes
2.2.2
15 minutes
2.2.3
20 minutes
2.2.4
25 minutes
2.2.5
30 minutes
2.2.6
40 minutes
2.2.7
50 minutes
2.2.8
60 minutes
2.2.9 *
70 minutes
3.
Heater
Operation
Mode
3.1.
Heater operation
mode for remote
3.1.1
Immediate start, automatic stop in 30
minutes
3.1.2
* Immediate start, automatic stop in 30