Autoplugin RCP-F2 Скачать руководство пользователя страница 7

7

When the ignition is turned on, button pressing keeps the current 

condition of the heater after the engine start. So, if the heater has operated 
before the engine start, it may continue to operate after the engine start (in boost 
heat mode). If the heater has been idle before the engine start, button press will 
inform RCP doesn’t let the heater to start in boost heat mode after the engine 
start. These functions are called quick enabling and disabling of boost heat 
mode respectively. Being activated these functions act for the current ignition 
cycle. Turning the ignition off cancels these functions.

Table 3

Button function

Ignition 
status

Engine 
status

Heater 
status

Description
(how to use)

Heater immediate
start

Off

Not running Off

One-touch heater start

Heater immediate 
stop

Off

Not running On

One-touch heater stop

One-time boost 
disable

On

Not running Off

Quick disabling of boost 
heat mode for short trips

One-time boost 
enable

On

Not running On

Quick enabling of boost 
heat mode in case of boost 
heat mode disabling by 
RCP settings or in case of 
one-time disabling by the 
button pressing

On

Running

Off

Boost extension

On

Running

On

This function lets the heater 
keep working after the 
engine has been switched 
off. It is useful with short 
stops in a trip.

When the engine runs, the button press is used to quickly enable of the 

boost heat mode (if boost heat mode was disabled early) and for the function 
called Boost Extension (if the heater operates in boost heat mode). Usually the 
heater is turned off right after the engine stops. If you want stop the engine with 
the heater keep working, you may use this button function.  Boost extension 
once activated will act while don’t you stop the heater manually or the heater 
stops automatically when the coolant achieves working temperature. 

Warning!

The parking heater must not be operated at filling stations, near 

sources of combustible vapours or dust or in enclosed spaces 

The fuel fired heater needs about 3 minutes to go to normal operation 

after startup. If your trip is planned to be shorter, it is highly recommended to 
use a button function called “one-time boost disable”.  This preserves the heater
from premature clogging.  Turn on the ignition, press the button, then start the 

Содержание RCP-F2

Страница 1: ...Autoplugin RCP F2 Version 7 3 Technical Description User Manual Rev A...

Страница 2: ...ter control by various impulses Heater status signals outputs Embedded remote control of the heater by using the original 3 button Ford car s key Remote cancellation of heater startup programmed in th...

Страница 3: ...e impulse If the heater is idle positive impulse on this input cancels the program start of the heater programmed by DIS Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Hea...

Страница 4: ...by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for multi functional but...

Страница 5: ...The output can be used to control an external device by time of heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates for programmed time the impulse of nega...

Страница 6: ...nted You can see series of double flashes in direction indicators of rear view mirrors when the heater starts to operate choose setting 6 1 2 to activate this function 3 The RCP adjusted by default on...

Страница 7: ...isabling by RCP settings or in case of one time disabling by the button pressing On Running Off Boost extension On Running On This function lets the heater keep working after the engine has been switc...

Страница 8: ...rresponds to a digit The LED and the direction indicators symbols in the DIS confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the thir...

Страница 9: ...lsius degrees 1 2 1 Not applied 1 2 2 Higher than 0 degrees 1 2 3 Higher than 10 degrees 1 2 4 Higher than 20 degrees 1 2 5 Higher than 30 degrees 1 2 6 Higher than 40 degrees 1 2 7 Higher than 50 deg...

Страница 10: ...Lock button s function for the heater remote control 3 3 1 Heater start only 3 3 2 Start of idle heater stop of operated heater 3 4 Lock button presses count to activate the RCP module 3 4 1 Heater co...

Страница 11: ...n of successful startup of the heater from remote control 6 1 1 Off 6 1 2 Series of double flashes 6 2 Indication of unsuccessful startup of the heater from remote control 6 2 1 Off 6 2 2 Series of si...

Страница 12: ...Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 8 Disable the output 8 Settings reset 8 1 1 Ap...

Страница 13: ...unadjusted condition after battery discharging or disconnection See chapter Preparation for Work to adjust the heater 2 No answer from the heater followed the start command The engine is hot no need t...

Страница 14: ...5 Unsuccessful start The heater was switched off spontaneously at startup Make diagnostics of the heater if the error occurs again 6 Operation cycle too short The heater was switched off spontaneousl...

Страница 15: ...RCP Remote Control Plug in electronic module for the heater remote control DIS Driver Information System of the instrument cluster BHM or Boost Heat Mode operational mode of the heater when it operate...

Страница 16: ...16 Autoplugin ES www autoplugin ru...

Отзывы: