Autoplugin RCP-F2 Скачать руководство пользователя страница 6

6

Preparation for Work

·

Focus II (2004-2007), C-Max (2003-2006)

Turn on the ignition and select in driver information system (DIS) menu:
Your settings -> Aux.heater programming ->Instant control -> Auto  

·

Focus II (2008-2011), C-Max (2007-2010), Kuga

Start the engine

and select in DIS menu:

Set>Menu –> Settings –> Auxiliary Heating  -> On ->Off ->On (again)

Basic Functions

1.

To start/stop the heater by using additional remote control, see 
documentation for the remote control. Functionality of the remote control 
depends on its possibilities, connection schemes and module’s settings.

2.

To start the heater by using the original Ford key press “Lock” button 3 
times on the key. Time intervals between presses must not exceed 20 
seconds. The unlocking of the vehicle or time interval excess will restart the 
counter of “Lock” button presses. Look at the direction indicators to be sure 
that RCP has received a command from the key.  Every button press on the 
key will be confirmed by direction indicators (if the car has been locked 
before).  Also if the car equipped by keyless entry system, you can use 
button on the door handle as “Lock” button to start the heater outside the car
(passive key must be presented). You can see series of double flashes in
direction indicators of rear-view mirrors when the heater starts to operate
(choose setting 6.1.2 to activate this function).

3.

The RCP adjusted by default only to switch the heater on by using Ford key.
If you also wish to switch the heater off, change the setting 5.1. As both the 
commands use the same combination of “Lock” presses, you should know a 
condition of the heater before a command send. Therefore we recommend 
you to activate the settings 6.4 – 6.6 to see the heater condition indicated by 
turn signals flashing in the rear-view mirrors. The possibility to stop the 
heater remotely may be useful in case of cancelation of the trip, including 
ones programmed by DIS.

4.

You can remotely cancel the start of the heater by a DIS program, if your
additional remote control can send stop command when the heater is idle. 
After stop command sending, DIS programs will be temporary disabled. 
Start the heater by any way or turn the ignition on enables DIS programs 
again.

5.

Additionally connected button gives several functions. Current function is 
defined by heater, ignition and engine conditions (see table. 3)

When the ignition is turned off, the button is used for immediate start or 

stop of the heater. Button press changes heater condition to another one: 
switches off the operated heater or switches on the idle heater.

Содержание RCP-F2

Страница 1: ...Autoplugin RCP F2 Version 7 3 Technical Description User Manual Rev A...

Страница 2: ...ter control by various impulses Heater status signals outputs Embedded remote control of the heater by using the original 3 button Ford car s key Remote cancellation of heater startup programmed in th...

Страница 3: ...e impulse If the heater is idle positive impulse on this input cancels the program start of the heater programmed by DIS Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Hea...

Страница 4: ...by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for multi functional but...

Страница 5: ...The output can be used to control an external device by time of heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates for programmed time the impulse of nega...

Страница 6: ...nted You can see series of double flashes in direction indicators of rear view mirrors when the heater starts to operate choose setting 6 1 2 to activate this function 3 The RCP adjusted by default on...

Страница 7: ...isabling by RCP settings or in case of one time disabling by the button pressing On Running Off Boost extension On Running On This function lets the heater keep working after the engine has been switc...

Страница 8: ...rresponds to a digit The LED and the direction indicators symbols in the DIS confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the thir...

Страница 9: ...lsius degrees 1 2 1 Not applied 1 2 2 Higher than 0 degrees 1 2 3 Higher than 10 degrees 1 2 4 Higher than 20 degrees 1 2 5 Higher than 30 degrees 1 2 6 Higher than 40 degrees 1 2 7 Higher than 50 deg...

Страница 10: ...Lock button s function for the heater remote control 3 3 1 Heater start only 3 3 2 Start of idle heater stop of operated heater 3 4 Lock button presses count to activate the RCP module 3 4 1 Heater co...

Страница 11: ...n of successful startup of the heater from remote control 6 1 1 Off 6 1 2 Series of double flashes 6 2 Indication of unsuccessful startup of the heater from remote control 6 2 1 Off 6 2 2 Series of si...

Страница 12: ...Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 8 Disable the output 8 Settings reset 8 1 1 Ap...

Страница 13: ...unadjusted condition after battery discharging or disconnection See chapter Preparation for Work to adjust the heater 2 No answer from the heater followed the start command The engine is hot no need t...

Страница 14: ...5 Unsuccessful start The heater was switched off spontaneously at startup Make diagnostics of the heater if the error occurs again 6 Operation cycle too short The heater was switched off spontaneousl...

Страница 15: ...RCP Remote Control Plug in electronic module for the heater remote control DIS Driver Information System of the instrument cluster BHM or Boost Heat Mode operational mode of the heater when it operate...

Страница 16: ...16 Autoplugin ES www autoplugin ru...

Отзывы: