8
engine. Now the heater will not operate with the engine while don’t you turn the
ignition off or use “one-time boost enable” function.
Additional Functions
By default RCP adjusted to perform only basic functions, such as start and
stop the heater using the remote control key. To turn on additional functions such
as battery monitoring, flashing with direction indicators in rearview mirrors, etc.
enter the module into Setup mode and activate the corresponding setup item (see
settings table 2).
A programming button and the brakes pedal are used to enter setup mode
and to change settings. You can use either additionally installed button, or front
passenger’s window close button on the driver’s door control panel as
programming button. Some car versions not allow using power window control
button as programming button. Use additional button in that case.
It is necessary to stop the engine and the heater before. Turn the ignition on,
press and hold the brakes pedal. Then 3 times press the programming button (press
and hold additional button for about 1.5 seconds, until the LED goes out). Both
direction indicators in the DIS confirm entering to the setup mode with 2 flashes.
Release the brakes pedal finally.
Each setup item in the settings table is a 3-digit code. To enter a digit of a
code, shortly press the button so much times, as corresponds to a digit. The LED
and the direction indicators symbols in the DIS confirm each button press: the
LED briefly goes off, the left direction indicator flashes one time when the first or
the third digit of code entered, the right direction indicator - when the second digit
of code entered. To complete a digit entering, press and release brakes pedal. The
DIS confirms it with one flash of both direction indicators simultaneously. When
all three digits entered, the module checks the code for validity and confirms it
with the direction indicators flashing. The both direction indicators flash twice
simultaneously in case of valid code and flash twice alternately in case of invalid
code.
If entered digit is not correct, press and release brakes button until the module
indicates an error. Enter the code once more in that case. Several codes can be
entered without exit of setup mode.
Turn the ignition off to exit setup mode. New settings are saved in the nonvolatile
memory of the module and stored there regardless of whether the module is
connected or not.
Attention:
If you start the engine without exit Setup mode, new
settings will not be saved in memory.
To reset the module to the factory settings, enter the code 8.1.1. Both direction
indicators in the CIP should flash three times, confirming command execution.
Then the module exits Setup mode and restarts.
To clear all the errors in the heater’s memory and thus unblock the heater, enter the
code 9.1.1. Both direction indicators flash five times confirming errors clearing. If