background image

8

engine. Now the heater will not operate with the engine while don’t you turn the 
ignition off or use “one-time boost enable” function.

Additional Functions

By default RCP adjusted to perform only basic functions, such as start and 

stop the heater using the remote control key. To turn on additional functions such 
as battery monitoring, flashing with direction indicators in rearview mirrors, etc. 
enter the module into Setup mode and activate the corresponding setup item (see 
settings table 2).

A programming button and the brakes pedal are used to enter setup mode 

and to change settings. You can use either additionally installed button, or front 
passenger’s window close button on the driver’s door control panel as 
programming button. Some car versions not allow using power window control 
button as programming button. Use additional button in that case.

It is necessary to stop the engine and the heater before. Turn the ignition on, 

press and hold the brakes pedal. Then 3 times press the programming button (press 
and hold additional button for about 1.5 seconds, until the LED goes out). Both 
direction indicators in the DIS confirm entering to the setup mode with 2 flashes. 
Release the brakes pedal finally. 

Each setup item in the settings table is a 3-digit code. To enter a digit of a 

code, shortly press the button so much times, as corresponds to a digit. The LED 
and the direction indicators symbols in the DIS confirm each button press: the 
LED briefly goes off, the left direction indicator flashes one time when the first or 
the third digit of code entered, the right direction indicator - when the second digit 
of code entered. To complete a digit entering, press and release brakes pedal.  The 
DIS confirms it with one flash of both direction indicators simultaneously. When 
all three digits entered, the module checks the code for validity and confirms it 
with the direction indicators flashing. The both direction indicators flash twice 
simultaneously in case of valid code and flash twice alternately in case of invalid 
code. 
If entered digit is not correct, press and release brakes button until the module 
indicates an error. Enter the code once more in that case. Several codes can be 
entered without exit of setup mode. 
Turn the ignition off to exit setup mode. New settings are saved in the nonvolatile 
memory of the module and stored there regardless of whether the module is 
connected or not. 

Attention:

If you start the engine without exit Setup mode, new 

settings will not be saved in memory. 
To reset the module to the factory settings, enter the code 8.1.1. Both direction 
indicators in the CIP should flash three times, confirming command execution. 
Then the module exits Setup mode and restarts.

To clear all the errors in the heater’s memory and thus unblock the heater, enter the 
code 9.1.1. Both direction indicators flash five times confirming errors clearing. If 

Содержание RCP-F2

Страница 1: ...Autoplugin RCP F2 Version 7 3 Technical Description User Manual Rev A...

Страница 2: ...ter control by various impulses Heater status signals outputs Embedded remote control of the heater by using the original 3 button Ford car s key Remote cancellation of heater startup programmed in th...

Страница 3: ...e impulse If the heater is idle positive impulse on this input cancels the program start of the heater programmed by DIS Table 1 X1 pin number Signal Name Polarity Wire colour 1 Heater_off White 2 Hea...

Страница 4: ...by the leading edge of the impulse This input is suitable for the most alarm systems and GSM modules connections in order to control the heater remotely X1 5 Button The input for multi functional but...

Страница 5: ...The output can be used to control an external device by time of heater operation Time of signal appearing is defined by the setting 5 1 When the heater operates for programmed time the impulse of nega...

Страница 6: ...nted You can see series of double flashes in direction indicators of rear view mirrors when the heater starts to operate choose setting 6 1 2 to activate this function 3 The RCP adjusted by default on...

Страница 7: ...isabling by RCP settings or in case of one time disabling by the button pressing On Running Off Boost extension On Running On This function lets the heater keep working after the engine has been switc...

Страница 8: ...rresponds to a digit The LED and the direction indicators symbols in the DIS confirm each button press the LED briefly goes off the left direction indicator flashes one time when the first or the thir...

Страница 9: ...lsius degrees 1 2 1 Not applied 1 2 2 Higher than 0 degrees 1 2 3 Higher than 10 degrees 1 2 4 Higher than 20 degrees 1 2 5 Higher than 30 degrees 1 2 6 Higher than 40 degrees 1 2 7 Higher than 50 deg...

Страница 10: ...Lock button s function for the heater remote control 3 3 1 Heater start only 3 3 2 Start of idle heater stop of operated heater 3 4 Lock button presses count to activate the RCP module 3 4 1 Heater co...

Страница 11: ...n of successful startup of the heater from remote control 6 1 1 Off 6 1 2 Series of double flashes 6 2 Indication of unsuccessful startup of the heater from remote control 6 2 1 Off 6 2 2 Series of si...

Страница 12: ...Engine runs RPM impulses 7 5 6 Ventilation is on during the heater operation potential 7 5 7 Ventilation is off during the heater operation potential 7 5 8 Disable the output 8 Settings reset 8 1 1 Ap...

Страница 13: ...unadjusted condition after battery discharging or disconnection See chapter Preparation for Work to adjust the heater 2 No answer from the heater followed the start command The engine is hot no need t...

Страница 14: ...5 Unsuccessful start The heater was switched off spontaneously at startup Make diagnostics of the heater if the error occurs again 6 Operation cycle too short The heater was switched off spontaneousl...

Страница 15: ...RCP Remote Control Plug in electronic module for the heater remote control DIS Driver Information System of the instrument cluster BHM or Boost Heat Mode operational mode of the heater when it operate...

Страница 16: ...16 Autoplugin ES www autoplugin ru...

Отзывы: