automatismos
pujol -
5
-
english
SPIDER PRO 600
PROGRammING
Description of the programming buttons
auto-programming
fig. 15
[1]. Control the motor with button “
a
” so that the transmission shuttle is engaged on the carriage and bring the door to the closed position:
. Keep pressing button “
a
” to cause the shuttle to move.
. Release the button to stop the movement.
. Press button “
a
” again to trigger movement in the opposite direction.
- Release button “
a
” before forcing the motor on the door.
[3]. Adjust the closed position using button “
a
”.
- Release button “
a
” before forcing the motor on the door.
[4]. Press “
B
” to launch the auto-programming cycle.
The door performs a complete Opening-Closing cycle.
- If the auto-programming is correct, warning light B goes out.
-
If the auto-programming cycle was not successful, warning light B continues to flash (2 flashes).
During auto-programming:
- If the door is moving, the movement is stopped and auto-programming is interrupted if any of the buttons are pressed.
It is possible to access auto-programming mode at any moment including when the auto-programming cycle has already been completed.
Note:
The remote controls supplied in the kit have already been memorised.
at this stage of the installation, the Spider Pro 600 motorisation is ready to operate.
Warning light legend:
Warning light a
Warning light B
. Triggering of auto-programming
. Memorising/clearing the remote controls
. Modifying a parameter value
. Parameter warning light selected
. Parameter value warning light
. Fault indicator warning light
. Use of forced operating mode
. Selecting a parameter
flashing
off