background image

Dual Gate Controller

24 Volt Gate Control System  DCB-05

Featuring

TrioCode

Technology

Part # 13253 (Manual v1.00)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание DCB-05

Страница 1: ...Dual Gate Controller 24 Volt Gate Control System DCB 05 Featuring TrioCode Technology Part 13253 Manual v1 00...

Страница 2: ...extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Aut...

Страница 3: ...eters 24 Transmitter Overview 25 Coding transmitter 25 Transmitter editing 26 Transmitter management 28 Code operation location empty 29 Code operation location used 29 Delete operation 29 Edit operat...

Страница 4: ...operty damage can result from failure to follow this warning Make sure that the safety obstruction detection system is working correctly and is tested every month Test as per the Installation Instruct...

Страница 5: ...oto electric beam must be tted correctly and tested for operation at regular intervals Extreme caution is recommended when using Auto Close mode All safety rules above must be followed In order for th...

Страница 6: ...domly generated from over 4 29 billion possibilities This greatly enhances the security of the system and makes code grabbing a thing of the past These transmitters also overcome interference issues b...

Страница 7: ...In addition the installer is guided through the steps of installation by rst adjusting the travel limits under motor power This can be done via the console keypad or via a hand held transmitter this a...

Страница 8: ...UTPUT 2 optional relay module coil drive OUTPUT 2 optional relay module coil drive OUTPUT 1 N C relay contact OUTPUT 1 COM relay contact OUTPUT 1 N O relay contact MOTOR 2 terminal 1 MOTOR 2 terminal...

Страница 9: ...Owner Installation Instructions Dual Gate Controller DCB 05 9 Control board layout 01 02 01 g 03 04 05 06 07 08 09 10 11 12 13 14 15 17 19 21 23 25 27 16 18 20 22 24 26 28 29 30 31 32 33 34...

Страница 10: ...4 Memory Usage Control input status display See page 31 Transmitter testing See page 31 Event history display See page 31 Periodic service cycle counter See page 32 Cycle and event counter See page 32...

Страница 11: ...rm the correct motor polarity is provided during the limit setup procedure Step 2 Installing antenna Mount the antenna at or above the height of the gate or fence whichever is higher for optimal recep...

Страница 12: ...imits Powering up the controller 05 g 06 g Dual Gate Controller can be used with drive units that use different methods to stop at the end of their travel The types supported are A Limit switch Open a...

Страница 13: ...When the close limit has been adjusted press SET to continue Fig 12 Note If the motor drives in the wrong direction UP closes gate DOWN opens gate the motor wires need to be swapped Step 6 Adjusting...

Страница 14: ...16 17 Step 6a Con rming Settings When the settings have being adjusted correctly drive the gate to the open stop and then press the SET Key As step 7A requires the gate to be open the controller will...

Страница 15: ...rocedure can be aborted at any time by pressing EXIT Step 1 Navigating To Timed Travel Menu To navigate to the Menu 10 2 from the main screen simply press PREV SET then NEXT Press SET to start the set...

Страница 16: ...on the motor wiring needs to be swapped Step 7 Setting Close Cycle Drive Time The controller is now ready for the close cycle drive time to be set Fig 27 To do this simply press and hold the DOWN key...

Страница 17: ...ile opening the motor is stopped If the motor is obstructed while closing the motor is stopped and then reversed to the open position Obstruction detection is achieved by monitoring the motor s curren...

Страница 18: ...lding the input will prevent closing Stop Stp Input Activated by STP terminal with N O switch by transmitter button with STP function assigned or by console s EXIT button Activating the STP input whil...

Страница 19: ...he allowable variation between the normal speed pro le and the controller to obstructions Increasing the value increases the force required to detect an obstruction Parameter AMP Limits Min Max Defaul...

Страница 20: ...puts will restart the countdown if the gate is OPEN Pedestrian access Auto Close This mode is selected by entering a non zero time for the Ped n A C parameter When selected the gate will Auto Close af...

Страница 21: ...he light stays on for after a cycle is adjustable The light can also be activated prior to the gate moving so that a warning can be given of the pending movement Note the light output can be selected...

Страница 22: ...motor 2 0 0 60 0 0 0 0 1 SEC 6 10 M2 NORMAL CLOSE TIME Normal close time for motor 2 0 0 60 0 0 0 0 1 SEC 6 11 MAX OVERRUN TIME Extra time allowed for cycle to complete beyond normal cycle time 0 60...

Страница 23: ...eter Min Max Default Menu No PE INPUT RESPONSE MODE Sets the PE response mode Options are OPEN and CLOSE cycles stop Close cycles stop or Close cycle reverse NOT USED OPN CLS stop CLS to stop CLS to r...

Страница 24: ...longer the button is held the faster the value changes 6 Press SET to SAVE setting Reload default setting 1 Press NEXT PREV buttons to display LOAD DEFAULT screen 2 Press SET to load the default value...

Страница 25: ...avigating to code transmitter menu 1 Press NEXT to navigate to the Menu 1 Fig 33 2 Press SET to enter code set procedure Step 2 Storing transmitter code 1 Controller will prompt to press one of the tr...

Страница 26: ...esponding to that button Available functions VAC Vacation Mode LGT Courtesy Light STP Stop OPN Open CLS Close SWP Swipe PED Pedestrian access OSC Open Stop Close OFF No action 3 Press SET to save chan...

Страница 27: ...sor over ID eld 2 Press NEXT to reveal Serial Number Fig 40 The serial number display is provided for additional means of identi cation The transmitter in this example has serial number 123456789 Step...

Страница 28: ...pied or if the location is empty a new transmitter can be coded Method 1 Go to the start of the list Step 1 Accessing the list menu 1 Press NEXT to navigate to the Menu 1 Fig 44 2 Press SET to enter t...

Страница 29: ...MITTER PROCEDURE will be initiated and the new transmitter will replace the existing one Note that the button functions and name of the existing transmitter will be transferred to the new transmitter...

Страница 30: ...or OPN wait for the gate to complete its cycle 3 Activate remote code set mode Using a small pin press and hold through the Coding Hole of the existing transmitter for two seconds Fig 56 4 Code new tr...

Страница 31: ...me a transmission is received If the transmitter button is stored in the controller memory and has a function assigned to it a second screen will be displayed that shows the transmitter details along...

Страница 32: ...e PARAMETER VIEWING AND EDITING If the service counter is not to be used it can be set to the maximum number 60 000 Menu 8 6 Counters The opener keeps a count of number of times a particular event occ...

Страница 33: ...limits Menu 9 2 Clr tx ers This option will clear the transmitter storage memory Menu 9 3 Backup tx ers This option saves a copy of the transmitter memory into a memory module connected to the contro...

Страница 34: ...l time from closed The setting is accessed from MENU 10 4 Set Pedestrian The time is adjustable in 1 second steps NOTE Before setting the pedestrian access position the gate must be in the fully close...

Страница 35: ...put1 And Output2 Outputs 1 and 2 are used to control a lock and a light Which output is to control which function and the way it is controlled is programmable If using these outputs make sure that the...

Страница 36: ...pads supplied with the battery charger kit part number 90188 Connect the SBY 3 charger board to battery box and to Dual Gate Controller as shown Fig 51 Reconnect power From menu 7 7 select the batter...

Страница 37: ...30 x 4 Button Transmitter Codes 2 Transmitter frequency 433 92 MHz Coding type Hopping Code No of code combinations Over 4 29 billion random codes Code generation Non linear encryption algorithm Trans...

Страница 38: ...38 Dual Gate Controller DCB 05 Owner Installation Instructions Purchased from Phone Installed by Date Serial No Notes and record...

Страница 39: ...condition j evidence of unauthorised repairs k any cost relating to damage caused by misuse negligence or failure to maintain the equipment in a proper working order as per clauses d through i l inst...

Страница 40: ...td No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change speci cation without notice E OE Automatic Technololgy...