DESCRIPTION OF STANDARD OPERATION

This section describes the standard operation of the control board
with the factory set default values. 

MOTOR CONTROL

.

The controller drives the motor in the appropriate direction as
instructed by the control inputs. Once a cycle is started the motor
will continue to travel until:

1.The controller is instructed to stop by a control input.
2.The motor's travel limit is reached.
3.The motor is obstructed, overloaded or stalls

When the control inputs instruct the control board to change the
motor direction, the controller brakes the motor, waits for the
motor to stop and then starts the motor in the other direction.

MOTOR OBSTRUCTION DETECTION (only supported
with limit switch type drive units)

If a motor is obstructed while opening, the motor is stopped. If the
motor is obstructed while closing, the motor is stopped and then
reversed to the open position. Obstruction detection is achieved
by monitoring the motor's curent and comparing it to the “nor-
mal” current profile for the motor. If the current of the motor rises
above the “normal” by the MARGIN AMP setting, then the motor
is said to be obstructed. In addition to the normal motor obstruc-
tion detection, motor overload and stall detection is provided to
protect the gate opener and controller.

MOTOR SPEED CONTROL

The motor's speed is controlled by varying the voltage applied to
the motor. When the motor is started its voltage in ramped up to
the OPEN or CLOSE Speed Voltage parameter. When the limit
switch of a drive unit is activated the motor is braked so as to
come to a rapid but gentle stop. 

LOCK RELEASE OUTPUT

The lock release output is configured to pulse for 0.5 seconds at
the start of each cycle. The output is turned on at the same time
the motors are started. The output is provided on OUTPUT1.

COURTESY LIGHT

The courtesy light is normally used to illuminate the driveway etc.
The light will be turned on each time the gate is activated (day or
night) and automatically turned off 1 minute after the drive cycle
has finished. The light can also be activated and deactivated by
pressing a transmitter button assigned the LGT function. The light
output is provided on OUTPUT2 (requires additional light relay
module RO-1).

OPEN / STOP / CLOSE (OSC) INPUT

(Activated by OSC terminal with N/O switch or by transmitter
button with OSC function assigned)
If the gate is stopped the OSC input will cause the gate to move
in the opposite direction to that last travelled. If the gate is mov-
ing the OSC input will cause the gate to stop.

PEDESTRIAN ACCESS (PED) FUNCTION 

(Activated by PED terminal with N/O switch or by transmitter
button with PED Function assigned)
The pedestrian access operation partly opens the gate to allow
pedestrian access but prevent vehicle access. The position the gate

leaf is driven to is automatically set to halfway during setting of
the travel limits, but can be manually selected. Pedestrian access
mode is entered when the input is activated and the gate is in the
closed position. If the gate is not in the pedestrian access mode,
the PED input will stop the gates if moving, or close the gates, if
stopped.  While in pedestrian access mode, the pedestrian access
position temporally becomes the open limit for the gate leaf. The
PED input then acts with an OSC type function. The pedestrian
access mode is exited when the gate is closed or when another
input is activated.

CLOSE (CLS) INPUT

(Activated by CLS terminal with N/O switch, by transmitter but-
ton with CLS function assigned or by console’s DOWN button)
Activating the CLS input will cause the gate to close. Holding the
input active will prevent opening.

SWIPE (SWP) INPUT

(Activated by SWP terminal with N/O switch or by transmitter
button with SWP function assigned)
Activating the the SWP input will cause the gate to be opened. If
the terminal input is held it will prevent the gate being closed. The
swipe input also effects P.E TRIGGERED AUTO CLOSE.

OPEN (OPN) INPUT

(Activated by OPN terminal with N/O switch, by transmitter
button with OPN function assigned or by console’s UP button)
Activating the OPN input will cause the gate to open. Holding the
input will prevent closing.

STOP (STP) INPUT

(Activated by STP terminal with N/O switch, by transmitter
button with STP function assigned or by console’s EXIT button)
Activating the STP input while the gate is moving will cause the
gate to be stopped. If the STP terminal is held it will prevent the
gate from being moved.

PHOTOELECTRIC SAFETY BEAM (P.E) INPUT

(Activated by PE terminal with N/C switch)
When the P.E input is active, the gate is prevented from being
closed. If the P.E input is triggered while the gate is closing, the
controller will stop the motors and then open the gate. The P.E
input has no effect while the gate is opening.

VACATION MODE

The controller supports a vacation mode where remote control
access is disabled. The mode is activated by pressing a 
transmitter button with the VAC function assigned until the con-
sole displays that vacation mode is enabled (approx. 5 seconds).
When activated any transmitter button which is assigned VAC
will be ignored. To turn the Vacation mode off simple press a
transmitter button with the VAC function assigned (Only requires
a brief activation.) Vacation mode can also be turned on or off
manually by editing the VACATION MODE parameter.

12

Содержание CB-19

Страница 1: ...COPY Warning Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property opener or controller damage Installation Instructions C...

Страница 2: ...GARAGE DOOR OPENERS GATE OPENERS REMOTE CONTROL ACCESS SOLUTIONS...

Страница 3: ...ING UP THE CONTROLLER 7 SETUP TRAVEL 7 LIMIT SWITCH AMP TRAVEL SETUP 9 RE PROFILING TRAVEL 10 SETTING TIMED TRAVEL 11 SETTING PEDESTRIAN POSITION 12 DESCRIPTION OF STANDARD OPERATION 13 CONTROL BOARD...

Страница 4: ...d for the installer to touch any console buttons during the coding process When all transmitters are coded a trans mitter storage report can be generated which can be easily transferred to a P C for r...

Страница 5: ...al 2 16 MOTOR 2 close limit switch input terminal 17 MOTOR 2 open limit switch input terminal 18 COM terminal for Terminals 16 17 19 20 19 MOTOR 1 close limit switch input terminal 20 MOTOR 1 open lim...

Страница 6: ...ansmitter Testing See Page 23 Event History Display See Page 23 Memory Usage See Page 23 Periodic Service Cycle Counter See Page 24 Parameter List 1 Open Lock Time 2 Close Lock Time 3 Pre Opn Lock Tim...

Страница 7: ...NG CONTROL SWITCH INPUTS When remote control operation is only required the CB 19 s con trol switch inputs are not utilised It is however strongly advised that a Photo electric Safety Beam be used to...

Страница 8: ...borted at anytime by pressing EXIT STEP 1 NAVIGATING TO LIMIT AMP TRAVEL MENU To navigate to the Menu 10 1 from the MAIN SCREEN simply press PREVto display MENU 10 followed by SET to display MENU 10 1...

Страница 9: ...console keypad or Button 1 and 4 of a transmitter After making adjustments to the limit switch positions always re approach the limit at full speed by driving the motor close a short distance and then...

Страница 10: ...lly close and open gate several times and learn the gates load and travel characteristics When the setup is complete the MAIN SCREEN will be displayed with the gate shown to be OPEN The Gate can now b...

Страница 11: ...g up the travel times The first allows the installer to drive the motor s so that the actual travel time can be recorded The second allows exact times to be entered Note The limit setting procedure ca...

Страница 12: ...me Save Settings PRESS Confirming Settings SETTING TIMED TRAVEL ENTER TIMES STEP 5A ENTERING TIMED TRAVEL PARAMETERS When the ENTER TIMES method is selected a list of parameters is provided to configu...

Страница 13: ...Activated by PED terminal with N O switch or by transmitter button with PED Function assigned The pedestrian access operation partly opens the gate to allow pedestrian access but prevent vehicle acce...

Страница 14: ...pplies 0 1 25 5 1 0 0 1 SEC 2 AMP TRIP LIMIT Motor drive electronics current limit 0 13 13 1 AMPS 2 PARAMETER AMP LIMITS MIN MAX DEFAULT STEP UNITS MENU MOTOR 1 OPEN LIMIT AMPS Sets Motor 1 open limit...

Страница 15: ...tions for safety reasons A P E beam must be used for these features to be activated AUTO CLOSE AFTER POWER UP Auto close after power up is normally not enabled for safety rea sons but can be enabled i...

Страница 16: ...configured to a SWIPE type input for pedestrian access This provides full functionality with the P E Triggered Pedestrian auto close function REMOTE CODE The controller supports the Remote Code Set fe...

Страница 17: ...input is used to alter the P E trig gered auto close feature so that P E triggered auto close is only initiated when the gateway is exited The direction of travel is determined by the sequence in whi...

Страница 18: ...yed Using the NEXT PREV buttons step through the list of parameters until the required parameter is displayed If the parameter s value is not to be changed then skip to step 7 when finished viewing th...

Страница 19: ...ode Transmitter menu will now be shown Press EXIT to return to the MAIN SCREEN and test the transmitter MENU 1 Code Transmitter PRESS Starting Code Transmitter Procedure Press Tx er Button LIST Press...

Страница 20: ...cheme which ties the store location to the transmitter s owner STEP 5 SELECTION OF ID OR SN DISPLAY When the cursor is moved to the ID SN indicator the UP and DOWN buttons toggle between displaying th...

Страница 21: ...tter s location within the list NOTE VIEW will not be shown if the transmitter is not stored 20 THE CONTROLLER PROVIDES A TRANSMITTER LISTING FACILITY WHICH ENABLES THE USER TO FIND A TRANSMITTER LOCA...

Страница 22: ...code operation is selected for a location that already contains a transmitter then the BASIC CODE TRANSMITTER PROCEDURE will be initiated and the new transmitter will replace the existing one Note tha...

Страница 23: ...for 2 seconds The example shows Button 1 being used but it could be any button It can even be an unused button on the existing transmitter STEP 5 CONFIRM TRANSMITTER BUTTON TO BE CODED Within 10 seco...

Страница 24: ...be displayed that shows the transmitter details along with the button pressed The example below shows the case when transmitter number 124 is activated by button 4 Note ID is selected for display MENU...

Страница 25: ...1234 When finished viewing simply press EXIT 24 Viewing Service Counter Service Counter CYCLES 60000 Viewing Counters 1 Open Cycles 1234 1 Open Cycles 2 Close Cycles 3 Ped Cycles 4 Warranty Cycles 5...

Страница 26: ...VAC 24VAC 30VDC 5AMPS RECEIVER TYPE UHF 433 92 MHz AM Receiver RECEIVER CODE STORAGE CAPACITY 30 x 4 Button Transmitter Codes TRANSMITTER FREQUENCY 433 92 MHz CODING TYPE Hopping Code No of CODE COMBI...

Страница 27: ...aims any liability of whatsoever nature in respect of any claim or demand loss or damage which arise out of a accidental damage to or normal wear and tear to the Product or to the Product s components...

Страница 28: ...GARAGE DOOR OPENERS GATE OPENERS REMOTE CONTROL ACCESS SOLUTIONS...

Отзывы: