equipment det
ails
122
equipment det
ails
123
3. Press the +/On button. On is shown in the
display and AutoOn flashes. Set the panel’s
main breaker to OFF.
When you get to the vehicle and AutoOn is
activated, de-activate AutoOn so that the heater
does not stop after 24 hours (the boiler cannot
be switched off when AutoOn is activated).
You can then step back with the left-hand
button in the settings and press Store in
all positions.
16. LoAD MonIToR Amp
This function is used if you do not want the
230V fuses to become overloaded. If the
vehicle’s total current consumption exceeds the
set value, the boiler’s electrical power will be
automatically reduced. On account of voltage
variations and tolerances, one can select
various control levels (for example, for 6A fuse,
one can choose either 5,6,7 Amp setting).
If the fuse does not hold, select a lower set
value. The function is disconnected in the
factory setting. To activate the function, you
must first light up the lower row of functions
(see item 11).
1. Press the button with the arrow until the
Amp symbol flashes. “OFF” is shown in
the display.
2. Press the -/Off button to activate and
set the function. The following values
can be set with +/On or -/Off buttons,
5,6,7,9,10,11,15,16,17.
3. Amp is shown in the display when the
panel returns to standby.
17. MEnU Menu
In the “Menu” setting one can activate a
number of functions. To activate the function
you must first light up the lower row of
functions (see item 11). To step between the
various functions, use the arrow keys.
OFFSET (Temperature adjustment)
With this function you can calibrate the
temperature on the panel if you notice that the
temperature (the stabilised room temperature)
does not correspond with the temperature
shown on the panel.
1. Press the button with the arrow until the
Menu symbol flashes. Press +On.
2. When OF is displayed, adjust the
temperature displacement with +/On or
-/Off (+/-5°C in intervals of 0.5°C).
3. Press Store to leave the OFFSET function.
PUMP 12V/PUMP AU.
The12V pump is used in the PU 12 setting even
if 230V is connected. In the PU AU position,
the 230V pump works, and when 230V is
1. Press the button with the arrow until the
symbol for automatic temperature change
flashes. The temperature and the “OFF”
text are shown on the display.
2. Press the +/On button. Set flashes and the
OFF text is shown in the display. Press +/On
to activate the function. “ON” is shown in
the display.
3. Press the left arrow key. The required
temperature is displayed. Then adjust the
temperature by pressing the +/On or
-/Off button.
4. Then press Store and the start time is displayed.
Adjust the start time (the same procedure as in
12) and press the “Store” button.
5. Now adjust the stop time and press
“Store” again. The text field shows the
required temperature and ON.
6. If you want the temperature change to
be repeated daily, select day 0. Auto is
shown in the display when the panel
returns to standby.
15. STARTInG THE
HEATER AUToMATICALLY Autoon
This function is used if you want the heater to
start automatically at a later time. The heater
works for 24 hours and then stops.
Automatic start is repeated the following week
as long as the function is activated.
To activate the function you must first light up
the lower row of functions (see item 11).
The function controls the panel’s main breaker.
1. Press the button with the arrow until the
AutoOn symbol flashes. “OFF” is shown in
the display. To activate AutoOn, press the
+/ On button or the -/Off button to close
the function.
2. The start time will be displayed. Set the
time in accordance with item 12 and press
“Store” to store the settings. “OFF” is
shown in the display.