TRUMATIC E 2400 L.P.G. HEATER WITH
ELECTRonIC ConTRoL, BUILT-In AIR
DISTRIBUTIon AnD THERMoSTAT
oPERATInG InSTRUCTIonS
Always observe the operating instructions and
‘Important operating notes’ prior to starting!
The vehicle owner is responsible for the correct
operation of the appliance!
The installer or vehicle owner must apply the
yellow sticker with the warning information,
which is enclosed with the appliance, to a
place in the vehicle where it is clearly visible
to all users (e.g. on the wardrobe door)! Ask
Truma to send you stickers, if necessary.
Control panel with sliding switch
a Slide valve
Heating – Off – Ventilation
b Slide valve for high setting (large flame
symbol) and low setting (small flame symbol)
Control panel with rotary switch
c ‘Heating’ rotary switch high setting (large
flame symbol) and low setting (small
flame symbol)
d ‘Off’ rotary switch
e ‘Ventilation’ rotary switch high setting
(large symbol) low setting (small symbol)
SWITCHInG on THE HEATInG
1. Remove cowl cap.
2. Turn on gas cylinder and open quick-acting
valve in the gas supply line.
3. Adjust desired room temperature at
rotary knob.
4. Switching the heating on:
Control panel with sliding switch:
Set the switch (a) to Heating and switch (b) to
the desired output setting.
Control panel with rotary switch:
Set the rotary switch to the desired output
setting (c). If the outside temperature is low,
switch to high setting.
The Trumatic E heater has been tested and
approved for operation, also when the vehicle
is moving. The burner with fan assistance
guarantees satisfactory operation, even
under extremely windy conditions. It may
be necessary to observe respective, country-
specific regulations for the operation of liquid
gas appliances when the vehicle is moving.
SWITCHInG on THE VEnTILATIon
Control panel with sliding switch:
Set switch (a) to Ventilation and switch (b) to
the desired output setting.
Control panel with rotary switch:
Set the rotary switch to the desired output
setting (e).
SWITCHInG off
Set the sliding switch (a) or the rotary switch
(d) to the centre. If the appliance is switched
off after a heating phase, the fan can
continue running in order to make use of
the residual heat.
If the appliance is not used for a prolonged
period of time, close quick-acting valve in the
gas supply line and turn off gas cylinder.
Green indicator lamp ‘Operation’ (under rotary
control knob)
When the appliance is switched on (heating or
ventilation) the green indicator lamp must be
illuminated (the fan is running). If the indicator
lamp is not illuminated, possibly check the (main)
trumatic e2400
switch. For this purpose observe respective
instructions of the vehicle manufacturer.
During the heating operation, while the flame
is burning, the green indicator lamp lights
up with twice the intensity. This also makes
it possible to determine the instantaneous
switching point of the room temperature.
fUSES
The device and control panel fuses are on the
electronic control unit on the device.
Device fuse (F1):
3.15 AT – slow –
(EN 60127-2-3)
Control panel fuse (F3):
1.6 AT – slow –
The fine-wire fuse must only be replaced by a
fuse of the same design.
RED InDICAToR LAMP ‘fAILURE’
Should a failure occur, the red indicator is
illuminated permanently. Possible causes for
the failure can be e.g. no gas, insufficient
combustion air, heavily soiled rotor, defective
fuse etc. Deactivate by switching off and then
switching on again.
Opening the window switch and closing it again
is the equivalent to switching off/on at the
control panel (e.g. performing a fault reset)!
Flash operation indicates that the operating
voltage is too low or too high for the appliance
(charge battery, if necessary). In Germany, always
notify the Truma Service Centre if problems are
encountered; in other countries the relevant
service partners should be contacted (see Truma
Service Booklet or www.truma.com).
ACCESSoRIES
1. Control unit VG 2
– for heaters of driver’s
cabs in tank vehicles, for the transportation
of hazardous goods according to ADR
(not to be used in combination with a
time switch).
2. outside switch AS
– for switching the
heater on and off from the outside of
the vehicle, e.g. for cargo space
heaters (available with 4 m or 10 m
connecting cables).
3. Acoustic signalling device ASM
– gives
an acoustic signal in event of a failure.
fig. H5:
fig. H3