46
47
power consumption
230V MAInS ELECTRICAL EqUIPMEnT
PoWER ConSUMPTIon
Please note:
It is possible that the 230V mains electrical
equipment may not all operate simultaneously.
A typical UK motorhome site mains hook up
point provides a maximum output of 10 amps
and on some continental sites the available
output may be as low as 5 amps.
If your loading exceeds the site supply it may
trip the site circuit breaker. Please check the
available mains output with your site operator.
APPLIAnCE
230V
12V
LP GAS
Watts
Amperes
Watts
Amperes
grams/hour
Dometic Fridge
135w
0.6a
Only when driving
11g/h
Ultraheat
500w
1000w
2000w
2.2a
4.3a
8.5a
12w
12w
12w
1.0a
1.0a
1.0a
N/A
N/A
N/A
S3002 Space Heater
N/A
N/A
12w
1.0a
30-280g/h
Ultrastore Water Heater
850w
3.7a
N/A
N/A
120g/h
Combi 4
2000w
8.5a
67w
max 5.6a
160-320g/h
C4002EL
2000w
8.5a
67w
max 5.6a
170-300g/h
Alde
N/A
N/A
6.0w
0.5a
245-405g/h
Alde
50Ow
1000w
2000w
2.2a
4.5a
8.5a
3.6w
3.6w
3.6w
0.3a
0.3a
0.3a
N/A
N/A
N/A
Caprice Cooker Hotplate
Caprice Grill
Caprice Oven
1 N/A
2 N/A
3 N/A
4 800w
N/A
N/A
N/A
N/A
N/A
3.5a
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
112g/h
112g/h
172g/h
N/A
116g/h
116g/h
Triplex Cooker Hotplate
Triplex Grill
Triplex Oven
1 N/A
2 N/A
3 N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
112g/h
112g/h
180g/h
115g/h
112g/h
SMEV hotplate
N/A
N/A
N/A
N/A
196-320g/h
Waeco Fridge
25w
0.108a
24w
2a
N/A
Battery Charger 25A
500w
3.6a max
N/A
N/A
N/A
lighting 12V (based on 10w bulb)
N/A
N/A
10w
0.8a
N/A
Water Pump
N/A
N/A
48w
4a
N/A
Cooker Hood
N/A
N/A
50w
4a
N/A
Microwave oven
1000w
4.4a
N/A
N/A
N/A
Similarly loadings on each circuit breaker
within the vehicle should be observed.
A label positioned close to the MCB’s will
identify which appliances within the vehicle
are fed from which MCB. Consulting the table
(Typical Appliance Consumption Figures) in
conjunction with this label, will give an indication
of which appliances can, and cannot, (site supply
allowing), be operated simultaneously.
WARnInG: never allow modifications of
electrical or LPG systems and appliances
except by qualified persons.
connecting
services
wiring diagram
Wiring of connecting cable and motorhome mains inlet
WARnInG: It is essential that connections are made exactly as shown. If terminal
markings are not in accordance with the diagram they must be ignored. If in doubt
consult a qualified electrician.
The legal length of the mains inlet cable is 25 ± 2 metres. When in use it must be fully
uncoiled and protected from traffic.
PITCH SUPPLY
oUTLET
CABLE PLUG
CABLE CoUPLER
MoToRHoME
MAInS InLET
connecting
services