Annex C
D - 1
LPG Safety in Caravans
Extract from BS 5482 (Part 2)
The safe use of LPG in caravans and non-permanent dwellings.
1)
2)
General
Propane and Butane are stored in cylinders as liquids under pressure. When the pressure is
released, ie. when the cylinder valve is opened, the liquid boils and gas is evolved. Both gases are
heavier than air and any leaking gas will tend to collect at a low level. The gas has a strong and
unpleasant smell which enables leaks to be easily detected. The gas is highly flammable and a
small quantity of gas in air can form an explosive mixture. Cylinders must be used and stored
always in a vertical position with the valve uppermost.
Safe Usa�e
To avoid accidents the following fundamental advice should be carefully read before using gas
appliances or changing gas cylinders.
a)
Always read and follow the user and maintenance instructions provided by the
manufacturers of gas equipment. Should any soot accumulate on pans, fire radiants, etc. or
any smell be produced, consult a competent installer on the correct maintenance and
adjustment of burners.
b)
Never check for gas leaks with a naked flame.
c)
Always tum off the gas cylinder valve(s) or inlet to the vehicle or other dwelling when gas
appliances are not in use.
d)
Never use gas appliances without adequate ventilation. All gas appliances require a
plentiful supply of fresh air for correct operation. Fixed ventilators or air inlets should not
be stopped up. Where practicable, turn off all appliances before retiring to bed, preferably
at the cylinder or inlet to the vehicle.
e)
Unless the appliance incorporates automatic ignition, when lighting an appliance always
make sure you apply a lighted match or tape to the burner
before
turning on the gas.
f)
If any appliance is disconnected for repair, maintenance, etc. ensure that the gas line is
capped off.
g)
If taps are stiff to operate or appear to be a source of leakage; call in a competent· installer
to rectify. LPG taps require a special grease.
h)
Always seek advice when in doubt.
3)
Routine Checkin2
It is essential to check the installation as follows:
a)
Flexible hoses and tubing should be regularly inspected and replaced when signs of
cracking or other deterioration appears. After replacement ensure that the ends are well
secured and leak tight.