"MOOD Harmony" - инновационное устройство для достижения эмоционального баланса. Подробное руководство пользователя можно бесплатно скачать с manualshive.com. Откройте для себя новый уровень гармонии и покоя с нашим продуктом.
Harmony
Utility Management System
User Instructional Handbook
Страница 1: ...Harmony Utility Management System User Instructional Handbook ...
Страница 2: ...oduction 03 www auto sleepers co uk harmony 03 Introduction 28 Digital Control Panel For Heaters and Air Conditioning Systems 30 The Digital Display 32 Functions 34 Changing Room Temperature 36 Changing Hot Water Level 38 Selecting Energy Source 40 Selecting Fan Level 42 Activating the Time Switch 44 Switching Lighting On Off 44 Setting the Time 45 Service Menu 50 Special Displays Warnings 54 Tech...
Страница 3: ...erstand these instructions If you are unsure of any point please contact your dealer distributor for advice before use The system has a number of key components that you will need to be familiar with before attempting to use the system these are The EC700 Power Supply Unit PSU a combined mains consumer unit and 12V controller generally located within a habitation area seat base The EC700 Control P...
Страница 4: ...elsewhere in this manual B Switch the PSU internal Power Converter OFF Locate the green Charger power switch on the PSU and ensure the switch is in the off position button out before connection to the mains supply C Connect the Hook up Lead Firstly connect the supplied hook up lead orange cable with blue connectors to the Leisure Vehicle and then connect to the mains supply D Check Residual Curren...
Страница 5: ...en on the button will be back lit blue Awning lights Pressing this button toggles the awning entry lights on and off When on the button will be back lit blue Battery Select Pressing this button changes the source of battery power between the vehicle battery and leisure battery This will also prioritise charging from the on board charger or solar panel depending on setting Settings Pressing this bu...
Страница 6: ...e lower navigation arrows can be used to easily switch between water and power level menu screens Pressing the home button will return you back to the main control panel The fresh water level is shown on the left of the screen whilst the waste water level is shown on the right Please Note that the levels on the screen will update more frequently if the pumps are switched on An audible warning will...
Страница 7: ...ult Pressing this will start or stop the automatic filling of the fresh water tank The filling process will automatically stop when the tank sensors detect it is full or after 7 minutes of filling whichever occurs sooner The button will be back lit blue while filling Tank Heaters This button will be back lit blue when active This doesn t mean that the tank heaters will be switched on The tank heat...
Страница 8: ... button switches the key press beep off and on Water level alarms pressing the water level alarm toggle button switches the water level alarms on and off Screen back light level pressing the button decreases the back light brightness while pressing the button increases the brightness Screen time out pressing the button decreases the screen time out time while pressing the button increases the scre...
Страница 9: ...a person down to earth or through a faulty appliance To ensure the RCD is working correctly the test button should be operated each time the vehicle is connected to the mains supply page 7 The Miniature Circuit Breakers MCB s operate in a similar way to traditional fuses and are provided to protect the wiring installation from overload or short circuit If an overload occurs the MCB will switch off...
Страница 10: ... Matt AGM batteries The system is also suitable for Lithium batteries with built in Battery Management Systems BMS Before fitting non standard batteries please check that the charging profile described in 3 3 is suitable for the type of battery by referring to the battery documentation or battery manufacturer Some vehicle installations can cater for two leisure batteries connected in parallel In t...
Страница 11: ... below This cut off level is designed to protect the vehicle battery from over discharge The 10 9V level ensures there is sufficient power in the battery to run the vehicle electronics and start the vehicle This cut off only applies to power drawn from the battery by the leisure equipment it will not protect the battery if you leave vehicle circuits switched on such as the road lights Leisure 9V P...
Страница 12: ...es humidity providing a figure also for information only from within that area It is hoped that the temperature information is a particularly useful figure for instance when checking on the vehicle remotely during cold weather Heat from other items in the vehicle in particular components from the heating system itself will have a bearing on the reading displayed by the Auto Sleepers LOCATE system ...
Страница 13: ...5V or above This cut off only applies to power drawn from the battery by the leisure equipment that is controlled by the control panel power switch it will not protect the battery from discharge by permanently connected equipment Leisure battery voltage high With control panel power on or off and leisure battery is selected as active battery and the voltage level rises above 15V Message on screen ...
Страница 14: ...ance premiums and provides extra peace of mind for just 95 per year The Control panel contains a small lithium battery to maintain the clock when no other energy supplies are available this will last in excess of 5 years under normal conditions The battery is a CR2032 3 0V The EC635 Communication module contains a special backup battery pack which should last in excess of 3 years under normal cond...
Страница 15: ...ations on the Truma CP plus control panel A defective Truma CP plus control panel may only be repaired by the manufacturer or the manufacturer s service department Never use LP gas appliances when refuelling in multi storey car parks in garages or on ferries Switch off the LP gas appliance on the Truma CP plus control panel and make sure that the LP gas appliance definitely cannot be switched on v...
Страница 16: ... recognised while searching for an appliance the function of the rotary push button changes see APPmodeinconjunctionwithaniNet Box onpage33 Initial start up Start up In order to perform the initial start up the following steps are required Switch on power supply 12V direct voltage for CP plus control panel and Combi and 230V mains voltage for air conditioning systems and Combi E Start the search o...
Страница 17: ...Stand by No heating function No hot water heating No operation of the air conditioning system No time switch function in the Truma CP plus control panel The CP plus control panel remains ready to receive commands via the Truma app or the infrared remote control of the air conditioning system This means that the connected appliances remain operable via the Truma App or the air conditioning system s...
Страница 18: ...ater and air conditioning system for an approximately constant temperature on the inside f AUTO Automatic air conditioning system is activated Requirements for operation with automatic air conditioning system The heater and air conditioning system must be connected Automatic air conditioning system ACC must be activated in the service menu see Service menu on page 13 Interior Climate Control The f...
Страница 19: ...d off a Boiler1 Hot water generator is switched on b eco2 Hot water temperature 40 C c hot Hot water temperature 60 C d boost1 3 Targeted rapid heating of boiler contents Boiler priority for a maximum time window of 40 minutes Then the water temperature is kept at the higher level for two post heating cycles about 62 C not Combi Diesel After reaching the water temperature heating of the room conti...
Страница 20: ...fault must be remedied and acknowledged on the Truma CP plus control panel Switch to Electrical energy type if the fault is persistent Special features in electric mode If the 230V power supply is interrupted and the 12V supply is switched on an fault code is shown on the display When the 230V power supply has been restored the heater is automatically started with the existing settings The fault c...
Страница 21: ...tic air conditioning system AUTO Not possible to select the fan level with the automatic air conditioning system The fan level of the air conditioning system is determined automatically Only ECO is available for heaters Select icon in menu bar 3 with rotary push button Change by tapping in the setting level Select desired fan level with rotary push button Tap the rotary push button to confirm the ...
Страница 22: ...ary push button Tap the rotary push button to confirm the value Select fan level Select desired fan level with rotary push button Tap the rotary push button to confirm the value Activate time switch ON Activate time switch with rotary push button ON Tap the rotary push button to confirm the value Deactivate time switch OFF Change by tapping in the setting level Deactivate time switch with rotary p...
Страница 23: ...n the menu bar 4 The hour display flashes Set the hours with rotary push button 8 The minutes display flashes when the rotary push button 8 is tapped again Set the minutes with rotary push button 8 Tap the rotary push button 8 to confirm the value Display 24 h mode Display 12 h mode The functions in the menu bars 3 4 of the Truma CP plus control panel are selectable in any order The operating para...
Страница 24: ...FF Example Set room temperature 23 C OFFSET 1 C Setpoint value for heater 22 C Presetting 0 C Celsius Example Set room temperature 23 C AC SET 2 C Setpoint value for air conditioning system 25 C Presetting 1 C Celsius ON The automatic air conditioning system function AUTO is activated Automatic air conditioning system function AUTO can be selected in the Room temperature menu AC SET appears in the...
Страница 25: ...n Aventa air conditioning systems with good circulation and not on the vehicle ceiling Truma dealers Truma partners are trained in correctly installing the automatic air conditioning system You can find our dealers Truma partners at www truma com 48 Harmony Service Menu hot 8 Showing the version number Display version number of heater air conditioning system Truma CP plus control panel or iNetBox ...
Страница 26: ...s that an operating parameter has reached an undefined state In this case the appliance concerned continues to operate As soon as the operating parameter is within the target range again this symbol goes off again automatically Cause eliminated return to setting level Tap the rotary push button Cause not eliminated return to the setting level Press the Back button W Warning 42 Fault code H Device ...
Страница 27: ...e cause has not been remedied the fault will occur again and the control panel will jump to the Fault menu level again Cause not eliminated return to the setting level Press the Back button E Fault 112 Fault code H Device H Heater A Air conditioning system hot 52 Harmony Faults Note This can take several minutes because of internal after runs of connected appliances Note In this case the warning i...
Страница 28: ...CP plus TIN Bus CP plus CI BUS TIN Bus CI BUS TIN Bus CI BUS Power supply 8 V 16 5 V Power consumption max 65 mA 100 background lighting 6 5 mA 10 mA Stand by Standby current 3 mA Off Weight approx 100g The Truma CP plus control panel is maintenance free In order to clean the front panel use a damp non scouring cloth If this is not sufficient use a neutral soap solution The Truma CP plus control p...
Страница 29: ...our Dealer as there is probably an equipment or wiring fault No or deficient supply from site Contact site Warden for assistance Other fault Contact your Dealer Reverse Polarity light is illuminated on PSU Mains Supply reversed The reverse polarity light is designed to illuminate when the Live and Neutral supply has been reversed crossed over If the light illuminates there is a problem with the si...
Страница 30: ...illuminate Battery not connected and or charged Install charged battery as per page 19 Power button on control panel not switched to on Turn power on at control panel Battery flat Battery fuse blown Recharge battery check fuses check charging voltage is present at battery Fuse blown Check all fuses are intact and the correct value fuse is installed as per fuse table Equipment switched off unplugge...
Страница 31: ...n triggered Contact Truma Service 170 Risk of low voltage 11 5V Use the electrical power from the battery sparingly e g restrict lighting Charge battery Truma Combi Heating System Gas Fault Code Possible Cause Remedy 17 Summer mode with empty water container Switch heater off and allow to cool Fill boiler with water 18 Warm air outlets blocked Check the individual outlet apertures Circulated air i...
Страница 32: ...rhome and caravan owner Contact the NCC approved Workshop on 01482 678981 01283 587960 Service 01386 853511 Parts 01386 842630 For out of hours support please refer to the support section of the Sargent web site www sargentltd co uk or email support sargentltd co uk If you have a question about an appliance always have information about the appliance type year of manufacture and factory number at ...
Страница 33: ...how to videos which will include any later updates or amendments Auto Sleepers reserves the right to alter specifications and prices at any time as materials and conditions demand Effective 1st November 2018 This literature supersedes all others Auto Sleepers Limited Orchard Works Willersey Nr Broadway Worcestershire WR12 7QF England Tel 44 0 1386 853338 Fax 44 0 1386 858343 MOTORHOMES OF EXCELLE ...