4. °C / °F temperature display
Select the temperature display °C (Celsius)
or °F (Fahrenheit).
Presetting: °C (Celsius)
6 12h/24h mode
Display time in 12 h (a. m., p. m.) / 24 h
mode.
Presetting: 24 h mode.
5. Changing the background lighting
Change the background lighting of the
Truma CP plus control panel in 10 levels.
7. Change language
Select the desired language (German,
English, French, Italian).
Presetting: English
Requirements for the automatic air conditioning system functioning as expected:
1. The air conditioning system and heater cover the entire area of the vehicle that is
supposed to be automatically air conditioned.
2. The room temperature sensor of the heater is the lead sensor of the automatic air
conditioning system and must therefore be in a suitable location, i.e.
•
in the area in which the required room temperature should be reached.
•
if possible not influenced by the outside temperature and sunlight.
•
not near to warm air ducts, cold air ducts or other sources of heat.
•
warm or cold air from the air outlets must not flow against the room temperature
sensor. Particular attention must be paid to this when adjusting the air throttles on
Aventa air conditioning systems
•
with good circulation and not on the vehicle ceiling
Truma dealers / Truma partners are trained in correctly installing the automatic air
conditioning system. You can find our dealers / Truma partners at www.truma.com.
48
Harmony - Service Menu
hot
8. Showing the version number
Display version number of heater, air conditioning system, Truma CP plus control
panel or iNetBox.
9. Presetting (RESET)
The reset function resets the Truma CP plus control panel back to the factory setting.
All settings will be deleted. Newly connected appliances are recognised and saved in
the Truma CP plus control panel.
•
Switch on the power supply 12V direct voltage for CP plus control panel and Combi
and 230 V mains voltage for air conditioning systems and Combi E.
•
Perform Reset
•
Select “RESET” with the rotary push button (8).
•
Tap on the rotary push button (8)
•
“PR SET” appears in the display.
•
Tap the rotary push button (8) to confirm.
After confirmation, the Truma CP plus control panel initialises itself.
“INIT..” appears on the display while this is in progress.
Example:
H 1.20.01 –> H = appliance; 1.20.01 =
version number
Appliance
C = Truma CP plus control panel
C = Truma CP plus control panel
CI-BUS
A = Air conditioning system
H = Heater
T = Truma iNet Box
Harmony User Guide oduction
049
Harmony - Service Menu
49
www.auto-sleepers.co.uk/harmony